D1260/D1260B Owner's Manual Part IV:
Part IV: Multi-Area Use
Working with Multiple Areas from a Single Command Center
Each of the functions described in the preceding section on Advanced Commands is presented as though your system includes only one area. If your system includes more than one area, it can be set up in one of two ways by the installing company:
•Each command center will only have access to the local area to which it is assigned, or
•Each command center may access either some or all areas beyond the one to which it is assigned. This factor is referred to hereafter as command center scope.
If your command center allows access to areas other than the local area (that is to say, has scope in other areas), then the command center will limit your access to those areas within the command center scope and for which your personal passcode has authority.
Given that you have access to areas beyond the local area, the means of accessing the various system functions depends upon the specific function.
For some functions, the command center allows you to select the area (or point) in which to perform the function. These “selectable” functions are:
•DISARM ?,
•MASTER ARM AREA ?.
•BYPASS A POINT? and
•UNBYPASS A POINT?
Another group of functions may automatically work in all areas in which you have passcode authority and which are within the scope of the command center. These are:
•Turning On Multiple Areas with a Passcode,
•Turning Off Multiple Areas with a Passcode,
•DISARM ALL ?,
•MASTER ARM ALL?,
•VIEW MEMORY?,
•WALK TEST?,
•RESET SENSORS ?,
•ADD PASSCODES ?,
•FIRE TEST?,
•VIEW POINT STATUS? and
•VIEW AREA STATUS?
Some functions may be
•PERIMETR INST? (Perimeter On Instant),
•PERIMETR DELAY ? (Perimeter On Delay),
•PERIMETR PART ? (Perimeter On Partial),
•EXTEND CLOSING ?,
•WATCH MODE ?,
•COMMAND 7 ?,
•COMMAND 9 ? and
•CHG DISPLAY ?.
A last group of functions don’t relate to specific areas and are thus
•SEND REPORT?,
•REMOTE PROG ?,
•CHG TIME/DATE ?,
•CHG SKEDS ?,
•DEL PASSCODES ?,
•CHG RELAYS ?,
•CHG PASSCODES ?,
•PRINT LOG ? and
•VIEW LOG?
View Area Status
Use this function when you need to know the status (whether armed or disarmed) of areas other than the one you’re in.
1.Ensure your keypad shows idle disarmed text.
2.Press the Menu> key to enter the Command Menu.
3.Press Next> repeatedly until you reach the VIEW AREA STAT ?> prompt.
Press the adjacent soft key.
68 | Bosch Security Systems 9/04 50410D |