MIC612 Thermal CameraInstallation en 23
4.4.4Installation Instructions
DANGER!
– ELECTRICAL SHOCK HAZARD
To reduce the risk of electrical shock, disconnect power before opening or working on any power supply unit. Power must be disconnected before replacing any fuse in the MIC PSU. Power supply units have power supplied whenever the power cord is inserted into the power source.
– MIC PSUs have a separate internal shield covering the power cable input terminal block (HD1). Only suitably qualified persons should remove this shield and connect the mains power cable. The shield MUST be
– The power supply cable shall have conductors of a maximum size of 12 AWG.
– Branch circuit protection incorporating a 15 A,
WARNING!
To meet UL standards and ratings, all external wires for installation applications must be routed through a permanently earthed metal conduit.
CAUTION!
Except for the Earth Link, heater links, and applicable fuses, the MIC PSUs have no user- adjustable parts. MIC cameras have no
CAUTION!
Bosch recommends using an uninterruptible power supply (UPS) in connection with a MIC camera/PSU installation.
NOTICE!
To maintain the IP rating of the power supply enclosure, install only listed or recognized conduit hubs or fittings with the same environmental rating as the enclosure in compliance with the installation instruction of the hub or fitting.
NOTICE!
Refer to the MIC Series Power Supply Installation Manual included with the PSU for full details on installing a MIC Series PSU and connecting to a MIC612 Camera.
Bosch Security Systems, Inc. | Installation Manual | F.01U.249.416 2.0 2012.09 |