Bosch Appliances MIC612 installation manual 4.4.1, Earth Link on PCB, 4.4.2, Fuse Ratings

Models: MIC612

1 80
Download 80 pages 8.05 Kb
Page 21
Image 21
4.4.1

MIC612 Thermal Camera

Installation en 21

 

 

NOTICE!

Only use the specified power supplies with the MIC612.

4.4.1

Earth Link on PCB

 

The printed circuit board (PCB) has one Earth Link option, near terminal block HD1, to allow

 

the PSU to be set up for different earthing schemes:

 

– If there is a separate connection between video screen and earth, the Earth Link should

 

be broken. This usually occurs on copper-connected systems where all of the copper

 

video coaxes are taken back to the control room to be connected to a central earth point.

 

– If fiber optics or other indirect connections are used to get data and video to and from

 

the control room, then the Earth Link should be left intact, as long as it is the only

 

camera-end earth reference point.

4.4.2

Fuse Ratings

 

 

 

 

 

 

 

 

 

 

The MIC PSUs for MIC612 cameras have four (4) off 20 mm fuses (numbers 13 - 16 in

 

 

Figure 4.3) in fuse holders. The ratings for these fuses are fixed on the low voltage secondary

 

 

side but change with input voltage on the high voltage primary side. The following table shows

 

 

the fuse values that should be fitted to provide proper protection for the MIC-240PSU-2 and

 

 

MIC-115PSU-2 power supplies. Note: FS 4 does not exist.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fuse

Fuse Function

Type

Rating for 240 V

Rating for 115 V

Rating for 24 V

 

 

 

ID

 

 

 

Primary

 

Primary

 

Primary

 

 

 

FS 1

MIC camera

Glass

1.6

A anti-surge (T)

1.6

A anti-surge (T)

1.6

A anti-surge (T)

 

 

 

 

protection

 

 

 

 

 

 

 

 

 

 

FS 2

Primary protection

Glass

200 mA quick blow

500 mA quick blow

2.5

A quick blow

 

 

 

FS 3

Heater protection 1

Glass

1.6

A anti-surge (T)

1.6

A anti-surge (T)

1.6

A anti-surge (T)

 

 

 

FS 5

Heater protection 2

Glass

1.6

A anti-surge (T)

1.6

A anti-surge (T)

1.6

A anti-surge (T)

 

Bosch Security Systems, Inc.

Installation Manual

F.01U.249.416 2.0 2012.09