Bosch Appliances MIC612 installation manual A.1.2, Commands, Thermal Camera

Models: MIC612

1 80
Download 80 pages 8.05 Kb
Page 69
Image 69
A.1.2

MIC612 Thermal Camera

 

en 69

 

 

 

 

 

 

 

 

 

 

 

 

 

Locked

Function

Command

Command

Description

 

 

Key

No.

 

 

 

 

On

99

Factory P/T Home Position

Recalibrates home position; can be used as an

 

 

 

 

 

Alarm Output.

 

 

 

 

 

 

 

 

On/Off

100

Record A

Activates/deactivates recording A.

 

 

On/Off

101

Record B

Activates/deactivates recording B.

 

 

On/Off

102

Wiper continuous

Turns on/off continous wiper mode.

 

 

On/Off

103

Wiper intermittent

Activates the wiper in Intermittent mode (the

 

 

 

 

 

wiper wipes twice, then turns off after 15

 

 

 

 

 

seconds).

 

 

 

 

 

 

 

 

On/Off

104

Wiper one shot

Activates (One shot) to wipe five times, then turn

 

 

 

 

 

off.

 

 

 

 

 

 

 

 

On/Off

105

Wash/Wipe

Activates wash/wip mode. Cameras moves to

 

 

 

 

 

designated washer preset (62), wiper starts

 

 

 

 

 

automatically.

 

 

On

997

FastAddress, display

Display the current FastAddress of the camera.

 

 

On

998

FastAddress, all units

Displays the current FastAddress of the camera

 

 

 

 

 

and programs all units.

 

 

On

999

FastAddress, unaddressed cameras

Displays and programs unaddressed MIC612

 

 

 

 

 

units.

 

 

 

 

 

 

 

 

Set

“1-99”

Pre-position Programming

Set ##–Programs a preset view.

 

 

Shot

“1-99”

Pre-position Recall

Shot ##–Recall programmed preset.

 

 

Set

100

Pre-position Menu

Enters the Pre-position menu.

 

 

Set/Shot

101

Autopan Left Limit

Set–Programs left limit.

 

 

 

 

 

Shot–Shows limit.

 

 

 

 

 

 

 

 

Set/Shot

102

Autopan Right Limit

Set–Programs right limit.

 

 

 

 

 

Shot–Shows limit.

 

 

 

 

 

 

 

 

Set

110

Factory P/T Home Position

Set–Recalibrate home position.

 

*

Set

802

Edit Password

Enters the Edit Password menu.

 

*

Set

899

Reset ALL

Restores all settings to original defaults and

 

 

 

 

 

clears all user-programmed settings.

 

 

 

 

 

 

 

 

Set

900

Edit Tour 1 (Standard)

Enters the Standard Tour Scene menu.

 

 

Shot

900

Edit Tour 2 (Custom)

Enters the Custom Tour Scene menu.

 

 

Set/Shot

901-999

Adds/Removes a Preposition Shot

Set ###–Adds preset.

 

 

 

 

from Tour 1

Shot ###–Removes preset.

 

A.1.2

 

Commands, Thermal Camera

 

 

 

 

 

 

 

 

Locked

Function

Command

Command

Description

 

 

Key

No.

 

 

 

 

On/Off

1

Scan 360°

Autopan without limits.

 

 

On/Off

2

Autopan

Autopan between limits.

 

 

On/Off

7

Play Custom Pre-position Tour

Activates/Deactivates the playback of a custom,

 

 

 

 

 

pre-position tour.

 

 

On/Off

8

Play Pre-position Tour

Activates/Deactivates the playback of a pre-

 

 

 

 

 

position tour.

 

*

On/Off

18

AutoPivot Enable

Enables/disables AutoPivot.

 

 

On/Off

50

Playback A, continuous

Activates/Deactivates continuous playback A.

 

 

On/Off

51

Playback A, single

Activates/Deactivates single playback A.

 

 

On/Off

52

Playback B, continuous

Activates/Deactivates continuous playback B.

 

 

On/Off

53

Playback B, single

Activates/Deactivates single playback B.

 

*

On/Off

69

Alarm Rule Activation/Deactivation

On–Enables all alarm rules.

 

 

 

 

 

Off–Disables all alarm rules.

 

 

 

 

 

 

 

*

On/Off

80

Digital Zoom Lock

Turns digital zoom on and off.

 

Bosch Security Systems, Inc.

Installation Manual

F.01U.249.416 2.0 2012.09

Page 69
Image 69