Bosch Appliances MIC612 Diagnostics Menu, Alarm Status, Bist, Internal Temp, High Temp Events

Models: MIC612

1 80
Download 80 pages 8.05 Kb
Page 50
Image 50
Diagnostics Menu

50 en On-Screen Display (OSD) Menus (Bosch Protocol)MIC612 Thermal Camera

6.9

Diagnostics Menu

 

 

 

 

The Diagnostics menu contains a list of diagnostic tools and events. Most of these menu

 

 

items are display items only; you cannot select different values to change.

 

 

 

 

 

 

 

 

Diagnostics

 

 

 

Exit...

 

 

 

 

 

Alarm Status...

 

 

 

 

BIST...

 

 

 

 

 

Internal Temp:

 

Deg F / Deg C

 

 

 

High Temp Events:

Deg F / Deg C

 

 

 

Highest Temp

 

Deg F / Deg C

 

 

 

Low Temp Events:

Deg F / Deg C

 

 

 

Lowest Temp:

 

Deg F / Deg C

 

 

 

Internal Humidity

%

 

 

 

Humidity Events

0

 

 

 

Security Access:

0

 

 

 

CTFID Access:

 

0

 

 

 

Restart Events:

 

 

 

 

Power-up Events:

0

 

 

 

Low-Volt Events:

0

 

 

 

Video Loss Events:

0

 

 

 

Total Time On

 

0hr 0min

 

 

 

Thermal Camera Test Pattern On/Off

 

 

 

Focus / Iris: Save and Exit

 

 

 

Alarm Status

 

 

 

 

 

Enters the Alarm Status menu and displays the real time status of alarm inputs and outputs.

 

 

Alarm Inputs 1 to 8, Alarm Outputs 1 to 2 (Closed or Open)

 

 

BIST

 

 

 

 

 

Enters the Perform Built-in Self Tests menu. YES to start test. If confirmed, the BIST tests

 

 

start and the results are displayed. Typical results are:

 

 

Data Flash:

PASS

 

 

 

 

FPGA:

PASS

 

 

 

 

Bilinx:

PASS

 

 

Internal Temp.

Displays the current temperature of the camera, in degress Fahrenheit and in degrees Celsius.

High Temp Events

Displays the number of times that the threshold of high temperature was exceeded.

Highest Temp

Displays the highest temperature reached, in degrees Fahrenheit and in degress Celsius.

Low Temp Events

Displays the number of times that the threshold of low temperature was exceeded.

Lowest Temp

Displays the lowest temperature reached, in degrees Fahrenheit and in degress Celsius.