Bosch Appliances MIC612 Getting Started, Establishing Control of the Camera, 5.1.1, 5.1.2

Models: MIC612

1 80
Download 80 pages 8.05 Kb
Page 30
Image 30
Getting Started

30 en Getting StartedMIC612 Thermal Camera

5

Getting Started

 

Install and wire the camera according to the instructions in this manual and in the manuals

 

that accompany the power supply and mounting devices. A typical system includes a

 

keyboard, matrix switcher, monitor, and appropriate wiring connections. Refer to the

 

individual product manuals for complete installation and setup instructions for each of the

 

system components.

5.1

Establishing Control of the Camera

 

The MIC612 supports two communication protocols (Biphase and RS-485), and both Bosch

 

and Pelco D and P (keyboard) controller protocols that allow you to send commands to the

 

camera and to receive information from the camera.

5.1.1

Establishing Control of the Camera via Biphase Protocol

 

 

 

NOTICE!

Biphase protocol works only with Bosch controller protocol. It does not work with Pelco controller protocol.

Biphase is the standard Bosch protocol used to send Pan/Tilt/Zoom control data. Biphase connections require a MIC-BP3 or a MIC-BP4 Biphase converter (sold separately).

 

Cable Type

Shielded Twisted Pair (STP)

 

 

System

Half-duplex, multidrop

 

 

Maximum Distance

1524 m (5000 ft) [Belden 8760 recommended]

 

 

Transmission Rate

31.25 KHz

 

 

Gauge

1.02 mm (18 AWG)

 

 

Termination Resistance

100 Ω

 

 

Terminal Connector

Screw terminals

 

 

Voltage

4 Vp-p

 

 

 

 

 

CAUTION!

The Biphase shield must be connected to the head end only.

5.1.2

Establishing Control of the Camera via RS-485 Protocol

 

 

Users can connect: via a) PC -> RS-232 ->RS-232 to RS-485 converter-> MIC612 or

 

 

b) PC ->USB to RS-485 -> MIC612.

 

 

RS-485 is capable of controlling a true multidrop network and is specified for up to 32 drivers

 

 

and 32 receivers on a single 2-wire bus. The MIC612 camera can be connected in a 2- or 4-

 

 

wire mode. Available connection protocols are: Pelco, Bosch OSRD (via a keyboard with RS-

 

 

485 output), Bicom over serial (via CTFID software; see the CTFID User Manual for installation

 

 

details), and Forward Vision protocols.

 

 

 

 

 

 

 

Cable Type

Shielded Twisted Pair (STP)

 

 

 

System

Half-duplex, differential, multidrop

 

 

 

Maximum Distance

1219 m (4000 ft)

 

 

 

Maximum Baud Rate

57.6 kb

 

 

 

Gauge

0.511 mm (24 AWG)

 

 

 

Wire Impedance

120 Ω

 