Communication Setup Menu

MIC612 Thermal CameraOn-Screen Display (OSD) Menus (Bosch Protocol) en 45

6.6

Communication Setup Menu

 

The Communication Setup Menu contains baud rate and Bilinx control settings.

Communication Setup

Exit...

 

* AutoBaud:

ON

* Baud Rate:

9600

Bilinx

 

Restore Defaults

 

* = Factory Setting

Focus / Iris: Select

AutoBaud

Turns on AutoBaud detection, which detects and adjusts the camera protocol and baud rate to match that of the controller. Options: ON (default setting), OFF. ON automatically accepts baud rates from 2400 to 57600.

Note: If stepping from 2400 to 57600 baud, you must first set the Baud Rate to 19200 for AutoBaud to detect the higher baud rate.

Baud Rate

Manually sets the baud rate when AutoBaud is set to OFF. Options are 2400, 4800, 9600 (default setting), 19200, 38400, and 57600.

Bilinx

Activates Bilinx control communication. (Only available when not connected to a Bilinx data interface unit.) Options: ON (default setting), OFF.