Bosch Appliances MIC612 installation manual 5.4.3FastAddress, Pelco Protocols, Nochange of address

Models: MIC612

1 80
Download 80 pages 8.05 Kb
Page 35
Image 35
To set an address for a camera without an address:

MIC612 Thermal Camera

Getting Started en 35

 

 

ON-998-ENTER: Displays and programs all cameras with or without an address in the system.

ON-997-ENTER: Displays the current address status of all cameras in the system simultaneously.

To set an address for a camera without an address:

1.Select the camera number that you want to FastAddress. The system displays the camera number on the keyboard and the image on the corresponding monitor.

2.Press #-ENTER(where # is the camera number without an address).

3.Press ON-999-ENTERto invoke an on-screen display of cameras on the system without an address.

4.Follow the on-screen instructions. You receive an on-screen confirmation when the FastAddress is complete.

To change or clear an address for a camera with an address:

1.Select the camera number that you want to FastAddress. The system displays the camera number on the keyboard and the image on the corresponding monitor.

2.Press #-ENTER(where # is the camera number with an address).

3.Press ON-998-ENTERto invoke an on-screen display of all cameras on the system, with or without an address.

4.Follow the on screen instructions. You receive an on-screen confirmation when the FastAddress is complete.

The table below identifies the setting of the thermal camera when you change the address of the optical camera.

Default Address, Optical

New Address, Optical Camera

Address, Thermal Camera

0

A number other than 0

The number of the optical

 

 

camera + 1

A number other than 0

0 or another number

-No change of address.-

You can change the address of the thermal camera via CTFID; there is no Aux code for this.

5.4.3FastAddress, Pelco Protocols

This section provides instructions to set a FastAddress with a Pelco keyboard or controller.

– The optical camera of the MIC612 with an address set to 0 responds to commands set to any address.

Pelco-Pprotocol must use addresses 1 to 32.

Pelco-Dprotocol must use addresses 1 to 254.

NOTICE!

A previously-configured MIC612 with an address above 32 (Pelco-P upper limit) or 254 (Pelco- D upper limit) can be used without readdressing the unit. However, no two (2) addresses can be the same. For example:

Pelco-P addresses above 32 are repeated in multiples of 32 (1, 33, 65, 97 are the same). Pelco-D addresses above 254 are repeated in multiples of 254 (1, 255, 509, 763 are the same).

To set FastAddress with a Pelco Keyboard:

1.Press and hold 95-PRESETfor two seconds to open the Pelco Setup menu.

2.Move the joystick to select the Command Lock menu.

3.Press the FOCUS or the IRIS button to turn Command Lock to OFF.

4.Move to the FastAddress menu and press the FOCUS button or the IRIS button to open the menu.

Bosch Security Systems, Inc.

Installation Manual

F.01U.249.416 2.0 2012.09

Page 35
Image 35
Bosch Appliances MIC612 5.4.3FastAddress, Pelco Protocols, Nochange of address, Default Address, Optical