Bosch Appliances MIC612 Thermal Temperature Threshold, Set the Temperature Threshold

Models: MIC612

1 80
Download 80 pages 8.05 Kb
Page 58
Image 58
Thermal Temperature Threshold

58 en Operation of the Thermal CameraMIC612 Thermal Camera

8.4

Triggering Alarms On Detection of Objects Outside of Set

 

Thermal Temperature Threshold

 

On models with the 35 mm thermal lens, you can set a High Temp Thermal Meter or Low

 

Temp Thermal Meter in order to trigger an alarm if the thermal spot meter identifies that the

 

temperature of an object in the view of the camera is outside of the temperature threshold set

 

in the system. The alarm input "High Temp Thermal Meter" identifies the high temperature

 

threshold for objects in view of the camera. If the camera detects an object with a

 

temperature that is higher than the threshold that is set in the system, it triggers an alarm.

 

The alarm input "Low Temp Thermal Meter" identifies the low temperature threshold for

 

objects in view of the camera. If the camera detects an object with a temperature that is lower

 

than the threshold that is set in the system, it triggers an alarm. For both inputs, the

 

temperature range is -40 °C to +150 °C, in 1 degree increments. The temperature scale is in

 

degrees Celsius only. The system allows you to set multiple high and low temperature inputs.

 

You can also set only a High threshold, or only a Low threshold; you do not need to set both.

 

To trigger the alarm, you must set the temperature threshold (high or low or both), and then

 

set the alarm rule.

 

Set the Temperature Threshold

 

To set the High Temp Thermal Meter input, follow these steps:

 

1.

Access the Alarm Setup menu of the OSD.

 

2.

Select the Inputs Setup submenu.

 

3.

Select the number of the input that you want to set.

 

4.

Select the value "High Temp Thermal Meter".

 

5.

Select the degree for the high temperature threshold (for example, 50 °C). The default

 

 

option is "Not Set."

 

6.

Exit the Inputs Setup submenu. The High Temperature threshold is now set.

To set the Low Temp Thermal Meter input, follow these steps:

1.Access the Alarm Setup menu of the OSD.

2.Select the Inputs Setup submenu.

3.Select the number of the input that you want to set.

4.Select the value "Low Temp Thermal Meter".

5.Select the degree for the low temperature threshold (for example, -10 °C). The default option is "Not Set."

6.Exit the Inputs Setup submenu. The Low Temperature threshold is now set.

Set the Alarm Rule

To set the rule for the thermal temperature alarm, follow these steps:

1.Access the Rule Setup submenu.

2.Select the number of the rule that you want to define.

3.Select "Input."

4.Select the appropriate Input value: "High Temp Thermal Meter" or "Low Temp Thermal Meter".

5.Select "Output."

6.Select the appropriate Output value. For example, in order to display the thermal temperature alarm, when triggered, on the OSD, select the value "OSD."

7.Select "Yes" when prompted to "Enable Rule" in order to activate the alarm rule.

8.Exit the Rule [number] submenu. The rule that you selected is now "Enabled" in the Alarm I/O Setup Menu.

F.01U.249.416 2.0 2012.09

Installation Manual

Bosch Security Systems, Inc.

Page 58
Image 58
Bosch Appliances MIC612 Thermal Temperature Threshold, Set the Temperature Threshold, Set the Alarm Rule