CAUTION!

 

Bosch recommends that only the installer calibrate the Azimuth Zero point. A recalibration to

 

the Azimuth Zero point may cause inaccurate compass headings.

 

 

10.5.2

Displaying Azimuth, Elevation, and Compass Headings

 

You can display only the azimuth/elevation readings or only the compass reading, or you can

 

display both readings at the same time. The MIC612 displays the azimuth/elevation readings

 

and the compass heading in the following way:

 

180 / –45 S

 

where:

 

180 is the Azimuth or the pan location in degrees.

 

–45is the Elevation or the tilt location in degrees.

 

S is the compass direction (cardinal or intercardinal).

 

1.

Press ON-95-ENTERto display the azimuth/elevation reading.

 

2.

Press ON-96-ENTERto display the compass heading.

 

3.

Press OFF-95-ENTERto hide the azimuth/elevation reading.

 

4.

Press OFF-96-ENTERto hide the compass heading.