Using the GWCON Interface Command

Maint: Fail

Number of maintenance failures

The following section describes the statistics displayed that are speci®c to the Token-Ring interfaces:

Physical address

Speci®es the physical address of the Token-Ring interface.

Network speed

Speci®es the speed of the Token-Ring network that connects to the interface. The Network Speed counter displays the number of packets that the interface can pass per second.

Max packet size (info)

Displays the maximum packet size con®gured for that interface. The Max Packet Size counter displays the maximum length, in bytes, of a packet that the interface transmits or receives. This counter is user-de®ned.

Handler state

Displays the current state of the Token-Ring handler. The Handler state counter displays the state of the handler after the self-test runs.

Ring status

Last Ring Status of the Token Ring interface.

SIGL

SIGNAL_LOSS

The interface has detected a loss of signal on the

 

ring.

 

 

 

HERR

HARD_ERROR

The interface is presently transmitting or receiving

 

beacon frames on the ring.

SERR

SOFT_ERROR

The interface has transmitted a report error MAC

 

frame.

 

 

 

BEAC

TRANSMIT_BEACON

The interface is transmitting beacon

 

frames to or from the ring.

LWF

LOBE_WIRE_FAULT

The interface has detected an open or

 

short circuit in the cable between the interface and the wiring

 

concentrator. The interface is closed and is at the state following

 

initialization.

 

 

 

ARMV AUTO_REMOVAL_ERROR The interface has failed the lobe

 

wrap test, which resulted from the beacon auto-removal process,

 

and has removed itself from the ring. The interface has closed and

 

is at the state following initialization.

RMVD REMOVED_RECEIVED

The interface has received a remove

 

ring station MAC frame request and has removed itself from the

 

ring. The interface is closed and is at the state following

 

initialization.

 

 

 

CO

COUNTER_OVERFLOW

One of the following error counters has

 

incremented from 254 to 255: Line, ARI/FCI, Frame Copy, Lost

 

Frames, Burst, Lobe wire faults, Removes received. This display

 

shows these error counters.

SSTA

SINGLE_STATION

The interface has sensed that it is the only

 

station on the ring.

 

 

RR

RING_RECOVERY

The interface observes claim Token MAC

Chapter 16. Con®guring IEEE 802.5 Token-Ring Network Interfaces 231

Page 267
Image 267
IBM SC30-3681-08 manual Using the Gwcon Interface Command