Monitoring PPP Interfaces (Talk 5)

 

Point to Point MAC/data-link on SCC Serial Line interface

 

Adapter cable:

 

 

 

 

V.35 DCE

RISC Microcode Revision:

 

0

 

 

 

 

 

 

 

 

V.24 circuit: 105 106 107 108 109

 

 

Nicknames:

RTS CTS

DSR

DTR DCD

 

 

PUB 41450:

CA

CB

CC

CD

CF

 

 

State:

ON

ON ON

ON

ON

 

 

Line speed:

 

 

unknown

 

 

Last port reset:

 

1 minute, 54 seconds ago

 

Input frame errors:

 

 

 

 

 

 

CRC error

 

 

 

 

0

alignment (byte length)

 

0

 

 

 

 

 

 

 

 

missed frame

 

 

 

 

0

too long (> 2182 bytes)

 

0

 

 

 

 

 

 

 

 

aborted frame

 

 

 

 

0

DMA/FIFO overrun

 

0

 

 

 

 

 

 

 

 

Output frame counters:

 

 

 

 

 

DMA/FIFO underrun errors

 

0

Output aborts sent

 

0

 

 

 

 

 

 

 

Net

Interface number as assigned by software during initial con®guration.

Net'

Base interface number as assigned by software during initial con®guration.

 

Note: For dial circuit interfaces, Net' is different from Net. For dial circuit

 

 

interfaces, Net' indicates the base interface (ISDN or V.25bis) that

 

 

the dial circuit uses.

 

Interface No

Type of interface and its instance number. The Point-to-Point interface type is PPP.

CSR Command and status register addresses of the base network.

Vec Interrupt vector address.

Self-Test: Passed

Total number of times the point-to-point interface passed its self-test.

Self-Test: Failed

Total number of times the point-to-point interface failed its self-test.

Maintenance: Failed

Total number of maintenance failures.

Adapter cable

Type of adapter cable that has been con®gured; for example, V.35 DTE.

V.24 circuit

Circuits being used on the V.24. Note: The symbol - - - in monitoring output indicates that the value or state is unknown.

Nicknames

Control signals Note: The symbol - - - in monitoring output indicates that the value or state is unknown.

PUB 41450

Pin assignments Note: The symbol - - - in monitoring output indicates that the value or state is unknown.

State State of the V.24 circuits (on or off). Note: The symbol - - - in monitoring output indicates that the value or state is unknown.

Chapter 33. Con®guring and Monitoring Point-to-Point Protocol Interfaces 507