IBM SC30-3681-08 manual Cir-defaults, Default Value 64

Models: SC30-3681-08

1 773
Download 773 pages 40.79 Kb
Page 464
Image 464

Con®guring Frame Relay Interfaces

For the status of the network to be considered network up, the number of events in error within the window must be less than n2 prior to any change in status.

Syntax:

 

 

 

set

cable*

 

 

 

cir-defaults

 

 

clocking*

 

 

encoding*

 

 

frame-size

 

 

idle . . .

*

 

 

ir-adjustment . . .

 

 

line-speed*

 

 

lmi-type n1-parameter

 

n2-parameter

 

 

n3-parameter

 

 

p1-parameter

 

 

t1-parameter

 

 

transmit-delay . . .

*

 

ty-parameter

 

*Note: The commands with an * following them are not available for FR dial circuit interfaces.

cable physical-interface-link-type data-connection-type Sets the cable type for the network physical link.

A DTE cable is used when you are attaching the router to some type of DCE device (for example, a modem or a DSU/CSU). A DCE cable is used when the router is acting as the DCE and providing the clocking for direct attachment.

The available options are:

Physical Interface Link Type

Data Connection Type

EIA 232 (RS-232)

DTE, DCE

V35

DTE, DCE

V36

DTE

X21

DTE, DCE

 

 

cir-defaults

Sets the default values for the circuit congestion parameters. The parameters are:

cir Sets the default value of cir to the value provided by a Frame Relay network provider.

Valid Values: 0 or 300 to 204 800 bps

Default Value: 64 000

bc Sets the default value of bc to the value provided by a Frame Relay network provider.

428MRS V3.2 Software User's Guide

Page 464
Image 464
IBM SC30-3681-08 manual Cir-defaults, Default Value 64, Physical Interface Link Type Data Connection Type