Con®guring Dial Circuits

Be aware that you cannot con®gure HDLC parameters of the dial circuit con®guration when you con®gure PPP or Frame Relay for ISDN. Physical layer parameters are con®gured on the ISDN interface.

For information on con®guring the PPP protocol, refer to ªChapter 25. Con®guring Serial Line Interfacesº on page 317 or refer to ªChapter 32. Using Point-to-Point Protocol Interfacesº on page 449.

For information on con®guring the Frame Relay protocol, see ªChapter 30. Using Frame Relay Interfacesº on page 387 or ªChapter 31. Con®guring and Monitoring Frame Relay Interfacesº on page 405.

For information on con®guring or monitoring SDLC interfaces, see ªChapter 37.

Using SDLC Interfacesº on page 537 or ªChapter 38. Con®guring and Monitoring

SDLC Interfacesº on page 539.

For more information on con®guring dial-in and dial-out interfaces, see ªUsing a

Dial-In Access to LANs (DIALs) Serverº in the Using and Con®guring Features.

For information on con®guring or monitoring X.25 interface, see ªChapter 27.

Con®guring and Monitoring the X.25 Network Interfaceº on page 327.

To return to the Circuit Config> prompt, use the exit command.

List

 

Use the list command to display the current dial circuit con®guration.

 

For more information about I.430 and I.431, see ªISDN I.430 and I.431 Switch

 

Variantsº on page 625.

 

 

Syntax:

 

 

list

 

Example:

 

Note: Options listed depend upon the type of interface used. All options may not

be shown for all interface types.

list

 

Any inbound

set

Bandwidth:

64

Base net:

1

Callback:

yes

Calls:

inbound

Destination name:

remote-site-sanfrancisco

Idle char:

7E

Idle timer:

= 60 sec

Inbound calls

allowed

Inbound dst name:

local-1

LID out address:

1234

LID used:

enabled

Net #:

2

Outbound calls

allowed

Priority:

8

SelfTest Delay Timer:

= 0 ms

Time slot:

1 4 5 8

Any inbound

 

Displays this setting when inbound calls that do not match any other dial

circuit are mapped to this circuit and accepted as inbound calls.

Chapter 47. Con®guring and Monitoring Dial Circuits 645

Page 681
Image 681
IBM SC30-3681-08 manual Variantsº on, Be shown for all interface types, Any inbound