Con®guring Frame Relay Interfaces

Example:

change permanent-virtual-circuit Circuit Number [16]?

Committed Information Rate in bps [64000]?

Committed Burst Size (Bc) in bits [64000]?

Excess Burst Size (Be) in bits [0]?

Assign Circuit Name: []?

Is the circuit required for interface operation [N]?

Does the circuit belong to a required group [N]?

What is the group name []?

Do you want to have data compression performed []?

Do you want to have data encryption performed []?

permanent virtual circuit

See page 406 for a description of the parameters.

switched-virtual-circuit

FR 4 Config>change switched-virtual-circuit

Circuit name []? svc01

Remote party number []? 12345

Remote party number numbering plan (E.164 or X.121) [E.164]?

Remote party number type (Unknown or International) [International]?

Remote party subaddress in hexadecimal []? 01

Remote party subaddress format (private or NSAP) [private]ı?

Requested outgoing Committed Information Rate (CIR) in bps [64000]?

Minimum acceptable outgoing Committed Information Rate (CIR) in bps [64000]?

Requested incoming Committed Information Rate (CIR) in bps [64000]?

Minimum acceptable incoming Committed Information Rate (CIR) in bps [64000]?

Requested outgoing Committed Burst size (Bc) in bits [64000]?

Requested incoming Committed Burst size (Bc) in bits [64000]?

Requested outgoing Excess Burst size (Be) in bits [0]?

Requested incoming Excess Burst size (Be) in bits [0]?

Idle timer in seconds [60]?

Establish circuit to learn remote protocol addresses [Y]?

Is multicast required for this circuit [Y]?

Are call-ins allowed for this circuit [Y]?

See page 409 for a description of the parameters.

Disable

Use the disable command to disable those features previously enabled using the enable command.

Syntax:

 

disable

cir-monitor

 

cllm

 

compression

 

congestion-monitor

 

dn-length-®eld

 

encryption

 

lmi

 

lower-dtr

 

multicast-emulation

 

no-pvc

 

notify-fecn-source

 

orphan-circuits

 

protocol-broadcast

Chapter 31. Con®guring and Monitoring Frame Relay Interfaces 413

Page 449
Image 449
IBM SC30-3681-08 manual Permanent virtual circuit