Monitoring Frame Relay Interfaces

information, see ªExcess Burst (Be) Sizeº on page 397.

ir-adjustmentincrement-% decrement-% minimum-IR

Sets the minimum information rate (IR) and the percentages for incrementing and decrementing the IR in response to network congestion.

The minimum IR, expressed as a percentage of CIR, is the lower limit of the information rate. The minimum percentage is 1 and the maximum percentage is 100. The default is 25.

When network congestion clears, the information rate is gradually incremented by the IR adjustment increment percentage until the maximum information rate is reached. The minimum percentage is 1 and the maximum percentage is 100. The default is 12.

When network congestion occurs, the information rate is decremented by the IR adjustment decrement percentage each time a frame containing BECN is received until the minimum information rate is reached. The minimum percentage is 1, and the maximum percentage is 100. The default is 25.

Example:

set ir-adjustment

IR adjustment % increment [12]?

IR adjustment % decrement [25]?

Minimum IR as % of CIR [25]?

Trace

 

Use the Trace command to enable packet tracing for individual circuits or the entire

interface and to list the tracing capability of all circuits on this interface. This

command can be used as a ®lter when tracing speci®c circuits or interfaces is

required. The default setting is to trace all circuits.

Syntax:

 

trace

all

 

circuitname

 

circuit#

 

list

Example:

 

trace 16

 

Enables packet tracing on circuit (PVC or SVC) with DLCI 16.

trace circuit phoenix

 

Enables packet tracing on circuit (PVC or SVC) named phoenix.

trace circuit all

 

Enables packet tracing on all circuits on this interface.

 

 

trace list

 

The following circuits are available for packet trace

Circuit Name

Circuit Number

--------------------------------

--------------

Unassigned

16

phoenix

25

jetsam

0

 

 

Lists the packet tracing capability of all circuits on this

interface.

 

444MRS V3.2 Software User's Guide

Page 480
Image 480
IBM SC30-3681-08 manual Information, see ªExcess Burst Be Sizeº on, Required. The default setting is to trace all circuits