Con®guring Frame Relay Interfaces

line hello packets between the lines. # is between 0 and 15 extra ¯ags. The default is zero (0). Setting this parameter provides 0 to 15 extra ¯ags between transmit frames. Table 59 lists the units and range values for serial interfaces.

Table 59. Transmit Delay Units and Range for the 2210 Serial Interface

Unit

Minimum

Maximum

 

 

 

Extra Flags

0

15

 

 

 

ty-parameter time

Con®gures the interval after which the device considers an existing congestion condition indicated by the receipt of a CLLM message to be cleared. If the device receives a CLLM message before the timer expires, the device resets this timer.

Valid Values: 5 to 30 seconds.

Default Value: 11 seconds.

Accessing the Frame Relay Monitoring Prompt

To access the Frame Relay operating commands and to monitor Frame Relay on your router, perform the following steps:

1.At the OPCON prompt (*), type talk 5.

2.At the GWCON prompt (+), enter the interface command to see a list of interfaces con®gured on the router.

3.Enter the network command followed by the network number of the frame relay interface. For example:

+net 2

Frame Relay Monitoring

FR 2 >

Frame Relay Monitoring Commands

This section summarizes and then explains the Frame Relay Monitoring commands. Use these commands to gather information from the database. Table 60 shows the commands.

Table 60. Frame Relay Monitoring Commands Summary

Command

Function

 

 

 

 

? (Help)

Displays all the commands available for this command level or lists the

 

 

options for speci®c commands (if available). See ªGetting Helpº on page

 

10.

 

Clear

Clears statistical information on the Frame Relay interface.

Disable

Disables CIR monitoring and congestion monitoring on the Frame Relay

 

interface.

Enable

Enables CIR monitoring and congestion monitoring on the Frame Relay

 

interface.

List

Displays statistics speci®c to the data-link layer and Frame Relay

 

management.

LLC

Displays the LLC monitoring prompt.

Notrace

Disables packet tracing capability for individual circuits or for the entire

 

interface.

Set

Sets CIR, Committed Burst Size, and Excess Burst Size for a Frame

 

Relay VC.

 

 

 

432MRS V3.2 Software User's Guide

Page 468
Image 468
IBM SC30-3681-08 manual Accessing the Frame Relay Monitoring Prompt, Frame Relay Monitoring Commands, Ty-parameter time