Using ELS

 

 

 

 

 

 

 

 

 

 

v Specify an event that stops message buffering and what action the system takes

when the event occurs.

 

 

 

 

 

v Send a formatted version of the buffer to a ®le at a remote server.

v View a speci®c number or all of the ELS messages in the buffer.

For speci®cs about the commands, see ªELS Message Buffering Con®guration

Commandsº on page 184 and ªELS Message Buffering Monitoring Commandsº on

page 210 .

 

 

 

 

 

 

 

 

 

The following example shows how to con®gure ELS message buffering.

MOS Operator Control

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*t 5 :Enter t 5 at the * prompt.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CGW Operator Console

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

+ev :Enter ev at the + prompt.

 

 

 

 

 

Event Logging System user console

 

 

 

 

ELS>a :Enter a for advanced at the ELS prompt.

 

Advanced ELS Console

 

 

 

 

 

 

 

ELS Advanced>li s :Enter li s to list status at the > prompt.

 

------------------Advanced ELS Configuration------------------------

Logging Status:

OFF

Wrap Mode:

ON

Logging Buffer Size: 0 KB

 

Stop-Event:

NONE

Stop-String:

NONE

 

 

Additional Stop-Action:

NONE

 

 

 

 

 

------------------------Run-Time Status-----------------------------

Has Stop Condition Occurred?

NO

 

Messages currently in buffer:

0

 

 

 

 

 

 

 

 

 

 

 

ELS Advanced>s b :Enter s b to set buffer size.

 

Enter buffer size of 0 KB or between 148 and 593 KB 148 ?

 

Buffer size set to 148 KB

 

 

 

 

 

 

ELS Advanced>s s e gw.26 :Enter s s e to set stop event eg. gw.26

 

Stop Event "GW.026" has been set

 

 

 

 

ELS Advanced>ex :Enter ex to exit Advanced to list gw.26

 

ELS>list ev gw.26

 

 

 

 

 

 

 

Level: C-TRACE

 

 

 

 

 

 

 

 

Message: Mnt nt %n int %s/%d

 

 

 

 

 

Active:

 

Count: 742

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ELS>a :Enter a to get back to advanced.

 

 

Advanced ELS Console

 

 

 

 

 

 

 

ELS Advanced>s s s Mnt nt 5 :Enter s s s to set the stop string.

 

Stop String set to "Mnt nt 5"

 

 

 

 

 

ELS Advanced>s s a ? :Enter s s a ? to query available stop actions.

NONE

 

 

 

 

 

 

 

 

 

 

APPN-DUMP

:Only available if APPN active and in the load image.

 

SYSTEM-DUMP

 

 

 

 

 

 

 

 

 

ELS Advanced>s s a s :Enter s s a s to set SYSTEM-DUMP stop action.

 

Stop Action has been set to SYSTEM-DUMP

 

 

ELS Advanced>s w off to :Enter s w on to set wrap mode off.

 

Advanced Wrap Mode set to OFF.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ELS Advanced>log sub gw all :Enter to enable the whole gw subsystem

 

ELS Advanced>s l on :Enter s l on to start the logging process.

 

Advanced Logging set to ON.

 

 

 

 

 

ELS Advanced>li s :Enter to list status of logging.

 

------------------Advanced ELS Configuration------------------------

Logging Status:

OFF

Wrap Mode: OFF

Logging Buffer Size: 148 KB

 

Stop-Event:

 

GW.026

Stop-String: Mnt nt 5

 

Additional Stop-Action:

SYSTEM-DUMP

 

 

 

------------------------Run-Time Status-----------------------------

Has Stop Condition Occurred?

YES

 

Messages currently in buffer:

7

 

 

 

 

 

 

 

 

 

 

 

ELS

Advanced>v a n :Enter to view all messages in buffer. For this

 

 

 

 

 

trivial example any viewing command suffices.

 

 

 

 

 

 

 

 

 

 

 

 

1

10:52:10

GW.026: Mnt nt 0 int Eth/0

 

 

2

10:52:10

GW.026: Mnt nt 5 int Eth/1->This triggers stop action

3

10:52:14

GW.026: Mnt nt 0 int Eth/0

Note that 5 more events

 

4

10:52:14

GW.026: Mnt nt 5 int Eth/1

get logged before

 

5

10:52:18

GW.026: Mnt nt 0 int Eth/0

logging stops and

 

6

10:52:18

GW.026: Mnt nt 5 int Eth/1

the stop action occurs.

 

7

10:52:22

GW.026: Mnt nt 0 int Eth/0

 

 

164MRS V3.2 Software User's Guide