Circuit config: 7>set net 6
Circuit config: 7>set timeslot23424
Circuit config: 7>list
Base net = 6
Idle character = 7E
Bandwidth = 64 Kbps
Timeslot =23424
Note: If this were an E1 circuit, the available timeslots would be 1 to 31.
Requirements and Restrictions for ISDN InterfacesRouter
The ISDN software requires the following models of the IBM 2210:
v127
v128
v14T
v24E - requires an ISDN adapter
v24T - requires an ISDN adapter
v24M - requires an ISDN adapter
v1S4
v1S8
v1U4
v1U8
Switches/Services Supported
The ISDN Basic Rate Interface (BRI) supports the following switches/services:
vAT&T5ESS (North America)
vDMS100 (North America)
vUSNI1 (North America National ISDN1)
vUSNI2 (North America National ISDN2)
vNET 3 (European ETSI)
vINS-Net 64 (Japan)
vVN3 (France Telecom)
vAUS TS 013 (Australia)
vI.430 (See “ISDN I.430 and I.431 Switch Variants”on page 625.)
The ISDN Primary Rate Interface (PRI) supports the following switches/services:
Switch names Validcommand
AT&T5ESS (NorthAmerica) 5ESS
AT&T4ESS (NorthAmerica 4ESS
Australia (AUSTEL) AUSPRI
INS-Net 1500 (Japan, NTT) INSPRI
National ISDN 2 (NorthAmerica) USNI2
NET 5 (Euro-ISDN, ETSI) NET5
Northern TelecomDMS (DMSPRI) DMSPRI
Native I.431 I431 (See “ISDN I.430 and I.431 Switch
Variants”on page 625.)
Using ISDN
618 MRS V3.2 Software User’s Guide
|
|
|
|
||||
||
|