Using ISDN

Table 79. ISDN Q.931 Cause Codes (continued)

 

Code

Cause

 

 

 

 

82

Identi®ed channel does not exist

 

 

 

 

83

A suspended call exists, but this call identity does not

 

 

 

 

84

Call identity in use

 

 

 

 

85

No call suspended

 

 

 

 

86

Call having the requested call identity has been cleared

 

 

 

 

88

Incompatible destination

 

 

 

 

91

Invalid transit network selection

 

 

 

 

95

Invalid message, unspeci®ed

 

 

 

 

96

Mandatory information element is missing

 

 

 

 

97

Message type nonexistent or not implemented

 

 

 

 

98

Message not compatible with call state or message type nonexistent or not

 

 

implemented

 

 

 

 

99

Information element nonexistent or not implemented

 

 

 

 

100

Invalid information element contents

 

 

 

 

101

Message not compatible with call state

 

 

 

 

102

Recovery on timer expiry

 

 

 

 

111

Protocol error, unspeci®ed

 

 

 

 

127

Interworking, unspeci®ed

 

 

 

 

 

 

Sample ISDN Con®gurations

The following topics show several typical ISDN con®gurations.

Frame Relay over ISDN Con®guration

Figure 36 shows how you can connect to a Frame Relay network through an ISDN network. In this con®guration, you set the data link on your dial circuits to Frame Relay.

Note: Dial circuits default to point-to-point (PPP) protocol. To change the protocol to Frame Relay, enter set data-link fr at the Config> prompt. A connection

will only be usable if the data link on both ends matches (for example, either FR to FR, or PPP to PPP).

 

N

 

ISDN

Frame

Router 2

Relay

 

 

 

Router 1

Figure 36. Frame Relay over ISDN Con®guration

Note: N could be either an ISDN TA connected to the FR switch, or an ISDN card in a FR switch.

616MRS V3.2 Software User's Guide

Page 652
Image 652
IBM SC30-3681-08 manual Sample Isdn Congurations, Frame Relay over Isdn Conguration