Con®guring and Monitoring BSC Relay

group group#

Displays the con®guration of a speci®ed group.

Set

 

Use the set command to con®gure the BSC interface parameters.

Syntax:

 

set

cable

 

clocking [internal or external]

 

code [ebcdic or ascii]

 

encoding [nrz or nrzi]

 

eotlink [yes or no]

 

frame-size

 

idle [sync or mark]

 

speed bps

 

syns number

cable Sets the cable used on the serial interface. The options are:

v

RS-232 DTE

v

RS-232 DCE

v

V35 DTE

v

V35 DCE

v

V36 DTE

v

X21 DTE

v

X21 DCE

Use a DTE cable when you are attaching the router to some type of DCE

device (for example, a modem or a DSU/CSU).

A DCE cable is used when the router is acting as the DCE and providing

the clocking for direct attachment.

clocking [internal or external]

Con®gures the BSC link's clocking. To connect to a modem or DSU,

con®gure clocking as external. To connect directly to another DTE device,

use a DCE cable, set the clocking to internal, and con®gure the clock

speed. For internal clocking, you must enter a valid line speed in the range

2400 - 2048000 bits per second.

Example:

 

set clocking internal

code [ebcdic or ascii]

Speci®es the code type that is used by this BSC device.

Default value: ebcdic

encoding [nrz or nrzi]

Con®gures the BSC interface's encoding scheme as NRZ (Non-Return to

Zero) or NRZI (Non-Return to Zero Inverted). NRZ is the default.

Chapter 40. Con®guring and Monitoring BSC Relay 573

Page 609
Image 609
IBM SC30-3681-08 Displays the conguration of a specied group, Use the set command to congure the BSC interface parameters