Bosch Appliances UPH-Z, UPH-2D, UPH-3D instruction manual 4Connections

Models: UPH-Z UPH-2D UPH-3D

1 64
Download 64 pages 19.24 Kb
Page 28
Image 28

28 en Configuring the Device

High Speed Pan/Tilt System

 

 

7.4Connections

Please take note of the particular UPH model that you have installed. All three versions, UPH- Z, UPH-2D, and UPH-3D Series, support Bilinx and Biphase telemetry control, i.e.: PTZ.

The camera menu setup of UPH-Z Series is done via the OSD, i.e.: AUX ON - 200 - Enter. The camera menu setup of UPH-2D and UPH-3D Series is done via two different AUX commands, i.e.: AUX ON - 46 - Enter (DinionXF main menu) and AUX ON - 801 - Enter (DinionXF installa- tion menu). See Figure 10.1 for more information about keyboard commands.

Bilinx is a Bosch two-way communication protocol that allows remote control, configuration, and updates over a video coax cable. Bilinx is available on all UPH models.

Biphase is used for communicating telemetry (control) and set up information with the UPH- Series units. Biphase does not pass the video signal from the UPH-Series units, so a separate video coax cable is required. Biphase should be wired with Belden 8760 or equivalent.

Biphase is available on all UPH models.

Note: If the UPH is the only unit connected, or the last unit in a daisy chain configuration, then turn ON dip-switch 1 of Biphase + Bilinx to terminate the data line. Turn OFF dip-switch 1 of Biphase + Bilinx for each UPH in a daisy chain (i.e. unterminated). A maximum of four (4) UPH units can be daisy chained together.

LTC5136 or equivalent

RS-232

 

Interface

 

Biphase

 

 

 

 

 

 

 

 

Box

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CCTV Monitor

Video

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

UPH Series: unitized pan/ tilt head

F01U.073.990 Version 1.0 2007.07

Instruction Manual

Bosch Security Systems

Page 28
Image 28
Bosch Appliances UPH-Z, UPH-2D, UPH-3D instruction manual 4Connections