28 en Configuring the Device | High Speed Pan/Tilt System |
| |
7.4Connections
Please take note of the particular UPH model that you have installed. All three versions, UPH- Z, UPH-2D, and UPH-3D Series, support Bilinx and Biphase telemetry control, i.e.: PTZ.
The camera menu setup of UPH-Z Series is done via the OSD, i.e.: AUX ON - 200 - Enter. The camera menu setup of UPH-2D and UPH-3D Series is done via two different AUX commands, i.e.: AUX ON - 46 - Enter (DinionXF main menu) and AUX ON - 801 - Enter (DinionXF installa- tion menu). See Figure 10.1 for more information about keyboard commands.
Bilinx is a Bosch two-way communication protocol that allows remote control, configuration, and updates over a video coax cable. Bilinx is available on all UPH models.
Biphase is used for communicating telemetry (control) and set up information with the UPH- Series units. Biphase does not pass the video signal from the UPH-Series units, so a separate video coax cable is required. Biphase should be wired with Belden 8760 or equivalent.
Biphase is available on all UPH models.
Note: If the UPH is the only unit connected, or the last unit in a daisy chain configuration, then turn ON dip-switch 1 of Biphase + Bilinx to terminate the data line. Turn OFF dip-switch 1 of Biphase + Bilinx for each UPH in a daisy chain (i.e. unterminated). A maximum of four (4) UPH units can be daisy chained together.
LTC5136 or equivalent
RS-232 | | Interface | | Biphase | |
| | | | |
| | Box | | | |
| | | | |
| | | | | |
| CCTV Monitor | Video | |
| | | | |
| | | | | |
| | | | | |
UPH Series: unitized pan/ tilt head
F01U.073.990 Version 1.0 2007.07 | Instruction Manual | Bosch Security Systems |