High Speed Pan/Tilt System

 

 

Auto Exposure Parameters Menu

The Auto Exposure Parameters menu is used to control the iris of the UPH-Z Series. In Auto- matic mode the iris of the camera/lens combination automatically reacts to light level changes. In Manual mode the user has full control of the iris.

AE PARAMETERS

1 - MODE:AUTOMATIC

Fig. 11.23 AE Parameters Menu

Feature

Description

Default

Options

 

 

 

 

MODE

Type of exposure control

AUTOMATIC

 

 

 

 

 

Parameters Mode - Infrared Menu

The Parameters Mode - Infrared Menu controls how the IR-cut filter of the camera/lens com- bination reacts to light changes.

 

PARAMETERS MODE - INFRARED

1

- INFRARED MODE ENABLING

NO

2

- AUTOM. INFRARED MODE

YES

3

- INFRARED DELAY TIME

025

4

- ICR OFF AE LEVEL

16

Fig. 11.24 Parameters Mode Menu

Feature

Description

Default

Options

 

 

 

 

INFRARED MODE

Continuous activation of infrared

NO

YES, NO

ENABLING

mode.

 

 

 

 

 

 

AUTOM. INFRARED

Enables the automatic function

YES

YES, NO

MODE

with automatic switching to infra-

 

 

 

red mode.

 

 

 

 

 

 

INFRARED DELAY TIME

Delayed recognition of daylight

25

005 - 255

 

(color) mode; the parameter is

 

 

 

shown in seconds.

 

 

 

 

 

 

ICR OFF AE LEVEL

Changes the point of switching the

16

1, 10, 16, 18,

 

IR-cut filter (ICR) between day and

 

20, 22, 24, 26

 

night time. The lower the value,

 

 

 

the earlier the ICR changes (i.e.

 

 

 

more sensitive to low light).

 

 

 

 

 

 

Dynamic Masking (UPH-Z Series only)

With dynamic masking, it is possible to create up to 24 masks so as to hide specific areas defined by the user. The masks are defined in the space and take into account the horizontal, vertical, and depth position of the zoom at the time of the setting.

The UPH automatically holds the position and the size of the masking, according to the area displayed.