40 en Configuring the SystemHigh Speed Pan/Tilt System

11.3

Motion Parameters Menu

 

The Motion Parameters menu is used to control the speed, limits, preset/patrol/autopan,

 

wiper-washer, and the alarm settings of the UPH.

 

 

 

 

 

MOTION PARAMETERS MENU

 

 

 

 1

- SPEEDS



 

 

2

- LIMITS



 

 

3

- PRESET/PATROL/AUTOPAN



 

 

4

- WIPER-WASHER



 

 

5

- ALARMS



 

 

 

 

 

 

Fig. 11.8 Motion Parameters Menu

11.3.1Speed Menu

The Speed menu is used to control the pan and tilt movement of the UPH in manual control mode using the joystick. See Figure 11.3.3 for setting pan & tilt speeds for the presets, patrols, and scans.

.

 

 

 

 

PAN SPEED MENU

 

 

SPEED MENU

 

 

 1

- SPEED 1...

0.6

gr./s

 1 - PAN SPEED



 

2

- SPEED 2...

1.0

gr./s

2 - TILT SPEED



 

 

3

- SPEED 3...

6.0

gr./s

3 - ZOOM DEPENDENT

NO

 

 

4

- SPEED 4...

10.0

gr./s

SPEED

 

 

 

 

 

 

 

 

 

 

 

5

- SPEED 5...

20.0

gr./s

 

 

 

 

6

- SPEED 6...

30.0

gr./s

 

 

 

 

7

- SPEED 7...

40.0

gr./s

 

 

 

 

8

- DEFAULT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TILT SPEED MENU

 

 

 

 

 

 

 1

- SPEED 1...

0.6

gr./s

 

 

 

2

- SPEED 2...

1.0

gr./s

 

 

 

3

- SPEED 3...

6.0

gr./s

 

 

 

4

- SPEED 4...

10.0

gr./s

 

 

 

5

- SPEED 5...

20.0

gr./s

 

 

 

6

- SPEED 6...

30.0

gr./s

 

 

 

7

- SPEED 7...

40.0

gr./s

 

 

 

 

DEFAULT

 

 

 

 

 

 

 

 

 

 

Fig. 11.9 Speed Menu

F01U.073.990 Version 1.0 2007.07

Instruction Manual

Bosch Security Systems

Page 40
Image 40
Bosch Appliances UPH-Z, UPH-2D, UPH-3D Motion Parameters Menu, Speed Menu, Wiper-washer, and the alarm settings of the UPH