High Speed Pan/Tilt System

Configuring the System en 45

 

 

Special Preset Parameters

The Special Preset Parameters menu can be used to make parameter settings. Increase the default value to increase the speed between presets or the scan speed.

SPECIAL PRESET PARAMETER MENU

 

 1 - PRESET SPEED REF.

: 20.0

2

- SCAN SPEED

: 20.0

3

- TILT SPEED

: 100

REDUCTION

 

6

- FIRST DWELL

00005

TIME

 

7

- FORCE PRST

NO

DW.TIME

 

8

- FORCE PRST

NO

SPEED

 

Feature

Description

Default

Options

 

 

 

 

PRESET SPEED REF.

Default value whenever a preset

20.0

0.1 - 100.0

 

position is stored.

 

 

 

 

 

 

SCAN SPEED

Reference speed used when a pre-

20.0

0.1 - 100.0

 

set position is recalled by the scan

 

 

 

function.

 

 

 

 

 

 

TILT SPEED REDUCTION

Tilt speed reducing factor with

100.0

0.1 - 100.0

 

respect to pan speed.

 

 

 

 

 

 

FIRST DWELL TIME

Time in seconds to dwell at preset

00005

00001 - 01000

 

position.

 

 

 

 

 

 

FORCE PRST DW.TIME

Forces the default dwell time value

NO

YES, NO

 

for all presets.

 

 

 

 

 

 

FORCE PRST SPEED

Forces the default speed value for

NO

YES, NO

 

all presets.

 

 

 

 

 

 

Bosch Security Systems