Bosch Appliances UPH-2D, UPH-Z, UPH-3D instruction manual Display Parameters, Offset Pan

Models: UPH-Z UPH-2D UPH-3D

1 64
Download 64 pages 19.24 Kb
Page 39
Image 39

High Speed Pan/Tilt System

Configuring the System en 39

 

 

The character being edited flashes and the joystick (up and down) can be used to change it. After making the change, confirm and continue to edit the text, or else exit with the Iris but- ton.

EDIT TEXT MENU

v _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

> 1ABC

2DEF

3GHI

4JKL

5MNO

6PQR

7STU

8VWX

9YZ

0()x

+,-.

 

Fig. 11.6 Edit Text Menu

Offset Pan

By default, the offset pan is +0.00. The value can be changed to move the default pan position of the unit to wherever is convenient. For example, if the installation requires that the NORTH position should be at 0.00 ° (pan), then an offset pan can be entered to compensate for any deviation from NORTH. After mounting, the NORTH position was found to be +41.37 ° (pan position); therefore, the offset pan should be set to - 41.37 ° to make the pan +0.00 ° position point to NORTH.

This has an effect on the Area Titles as defined in the Area Position menu. In the above exam- ple, after the offset pan has been set to -41.37 °, the Area Text Menu "1 - Area" could be changed to "1 - NORTH" to display NORTH on the screen at pan +0.00 ° position.

11.2.3Display Parameters

The Display Parameters menu is used to enter the settings menus for the device movement parameters.

DISPLAY PARAMETERS

 

 1

- OSD VIDEO ENABLING

: YES

2

- VIDEO CHARACTER TYPE

: 000

3

- HORIZONTAL DELTA

: 000

4

- VERTICAL DELTA

: 000

5

- ADDRSS NUMBER

YES

Fig. 11.7 Display Parameters Menu

OSD Video Enabling

Set to YES to superimpose the menu text over the video signal

 

from the camera. Set to NO to have a blue screen behind the

 

menu TEXT.

 

 

Video Character Type

Set to 0 to make the background of the text to transparent; set to

 

1 to make it black.

 

 

Horizontal Delta/Vertical

These set the position of reference to the titler so that the text

Delta

can be centralized.

 

 

Address Number

If enabled, the address number of the unit is shown at the top left

 

of the screen during normal operation.

 

 

Bosch Security Systems

Instruction Manual

F01U.073.990 Version 1.0 2007.07

Page 39
Image 39
Bosch Appliances UPH-2D, UPH-Z, UPH-3D instruction manual Display Parameters, Offset Pan