42 en Configuring the System | High Speed Pan/Tilt System |
|
|
11.3.2Limits
The Limits menu sets the movement limits for the UPH. These limits apply to all presets, auto- pan and patrols, including manual operation of the UPH using the joystick. After the limits are set in the OSD and the UPH moves into the "limited pan and tilt zone", it will not move outside of those limits until they are altered in the OSD or the UPH is reset. On reset, the UPH returns to within the limited pan and tilt zone.
LIMITS MENU |
|
| |
1 | - ENABLE PAN LIM. | : | NO |
2 | - START PAN | : + | 0.00 |
3 | - END PAN | : + | 0.00 |
4 | - ENABLE TILT LIM. | : | NO |
5 | - START TILT | : + | 0.00 |
6 | - END TILT | : + | 0.00 |
7 | - COMPL. ROTATION | : | YES |
8 | - RAMP TYPE | : | 012 |
Fig. 11.10 Limits Menu
.
Feature | Description | Default | Options |
|
|
|
|
ENABLE PAN LIM. | Enables limits and values in | NO | YES, NO |
| degrees taken by the device in |
|
|
| pan. |
|
|
| Enables or disables complete rota- |
|
|
| tion for scan/patrol/autopan move- |
|
|
| ments (this function is useful when |
|
|
| using accessories with external |
|
|
| cables, such as infrared spotlights, |
|
|
| where continuous rotation of the |
|
|
| UPH could break the accessories |
|
|
| themselves). |
|
|
|
|
|
|
START PAN | Enables the location that the UPH | +0.00 | |
| begins to pan. |
| +180.00° |
|
|
| |
|
|
|
|
END PAN | Enables the location that the UPH | +0.00 | |
| stops panning. |
| +180.00° |
|
|
| |
|
|
|
|
ENABLE TILT LIM. | Enables limits and values in | NO | YES, NO |
| degrees taken by the device in tilt. |
|
|
|
|
|
|
START TILT | Enables the location that the UPH | +0.00 | |
| begins to tilt. |
| +90.00° |
|
|
| |
|
|
|
|
END TILT | Enables the location that the UPH | +0.00 | |
| stops tilting. |
| +90.00° |
|
|
| |
|
|
|
|
COMPL. ROTATION | Enables the search for the shortest | YES | YES, NO |
| route during scan, patrol, and |
|
|
| autopan movements. |
|
|
|
|
|
|
RAMP TYPE | Changes start and stop times for | 012 | 000 - 012 |
| the UPH. The higher the number, |
|
|
| the greater the acceleration/decel- |
|
|
| eration during starting/stopping. |
|
|
|
|
|
|
F01U.073.990 Version 1.0 2007.07 | Instruction Manual | Bosch Security Systems |