11.3.4Wiper-Washer
Select UPH Pan/Tilt models have a wiper option used to operate an (external) pump for clean- ing the glass. The spray for cleaning the glass is on the outside of the pan/tilt (see
Figure 11.16). For cleaning, the UPH must be positioned with the glass facing the spray. Start the pump for the glass cleaning liquid and then start the wiper. It is necessary to set a preset position corresponding to the spray which is loaded when the “wiper” function is started. For washer models with a level sensor, the UPH displays an on-screen message when the level of liquid in the tank is too low (only if using a pump with high discharge head from the UPTWASA Series).
Fig. 11.16 Wiper-washer Function
|
| ||
1 - ENABLED | : | NO | |
2 | - PRESET POSITION : | 00001 | |
3 | - RELAYS NR. | : | 00002 |
4 | - PUMP DELAY | : | 00003 |
5 | - WIPER DURATION | : | 00005 |
6 | - DELAY WIPER OFF : | 00002 |
Fig. 11.17 Wiper-washer Menu
Feature | Description | Default | Options |
|
|
|
|
ENABLED | Enables the wiper function. | NO | YES, NO |
|
|
|
|
PRESET POSITION | Enables the preset position to be | 00001 | 00001 - |
| reached. |
| 00250 |
|
|
|
|
RELAYS NR. | Enables the relay to activate for | 00002 | 00001 - |
| water pump control. |
| 00002 |
|
|
|
|
PUMP DELAY | The delay between the pump com- | 00003 | 00001 - |
| mand and when the wiper starts |
| 00050 |
| moving. |
|
|
|
|
|
|
WIPER DURATION | The amount of time that the wiper | 00005 | 00001 - |
| wipes. |
| 00050 |
|
|
|
|
DELAY WIPER OFF | The amount of time that the wiper | 00002 | 00001 - |
| wipes without water. |
| 00050 |
|
|
|
|