nReassembling Notes
•When reinstalling the scanner motor, fit it in the latch provided on the scanner frame with the connector facing up and then secure it with the screw. (See page
•When setting the scanner frame ASSY back into place,
-secure the grounding terminal to the scanner frame ASSY with the screw and route the grounding wire around boss "x" (as shown on page
-route the CIS harness through the scanner frame ASSY (or connect the CIS harness to the CIS unit if mounted),
-route the
•When reinstalling the CIS unit, first connect the CIS harness, insert the left end under the arm of the scanner frame, put the CIS unit into the scanner frame, and move it to right (see the illustration given on page
•When attaching the CIS film, align the right, left and rear edges of the cutout with those provided in the scanner frame and fit its two tabs into the scanner frame, as illustrated on page
•When connecting the scanner motor harness to the scanner motor connector, take care not to bend the shield film.
•Once removed, the shield film becomes unusable and a new part will have to be put back in.
IV - 20