V - 40
WSW28 (Function setting 6)
Selector
No. Function Setting and Specifications
1
|
3
Transmission level of DTMF high-
band frequency signal
No. 123
000 : 0 dB
001 :+1 dB
010 :+2 dB
011 :+3 dB
100 : 0 dB
101 : -1 dB
110 : -2 dB
111 : -3 dB
4
|
6
Transmission level of DTMF
low-band frequency signal
No. 456
000 : 0 dB
001 :+1 dB
010 :+2 dB
011 :+3 dB
100 : 0 dB
101 : -1 dB
110 : -2 dB
111 : -3 dB
7Current available resolution in
receiving
0: Sends the 1: Switches the
current resolution resolution to the
statement lower level
8Not used.
lSelectors 1 through 6: Transmission level of DTMF high-/low-band frequency signal
These selectors are intended for the manufacturer who tests the equipment for the Standard.
Never access them.
lSelector 7: Current available resolution in receiving
If this selector is set to "0," the equipment will send the resolution statement to the calling station,
telling the maximum capacity of the equipment independent of the current memory space
available.
If this selector is set to "1," the equipment automatically switches the resolution to the lower level
(superfine fine standard) if the memory space is insufficient to receive data at the designated
resolution.