WSW04 (TRANSFER facility setting)

Selector

Function

 

 

Setting and Specifications

No.

 

 

 

 

 

 

 

 

 

 

 

 

 

1

Earth function in transfer facility

 

0: Provided

1: Not provided

 

 

 

 

 

 

 

2

 

 

 

 

 

 

Not used.

 

 

 

 

 

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

No.

5

6

 

 

5

 

 

0

0

:

200 ms

 

Earth time length for earth

 

0

1

:

300 ms

6

function

 

1

0

:

500 ms

 

 

 

 

 

1

1

:

700 ms

 

 

 

 

 

 

 

 

 

No.

7

8

 

 

7

Break time length for flash

 

0

0

:

80 ms

 

 

0

1

:

110 ms

 

function

 

8

 

1

0

:

250 ms

 

 

 

 

 

1

1

:

500 ms

 

 

 

 

 

 

 

NOTE: Selectors 1 and 5 through 8 are not applicable in those countries where no transfer facility is supported.

Selector 1: Earth function in transfer facility

This selector determines whether or not the earth function is added to the transfer setting menu to be accessed by the function switch.

Selectors 5 and 6: Earth time length for earth function

These selectors set the short-circuiting time length of the telephone line (La or Lb) to ground.

This setting is effective only when the earth function is selected for the R key by using the function switch.

Selectors 7 and 8: Break time length for flash function

These selectors set the break time length.

This setting is effective only when the flash function is selected for the R key by using the function switch.

V - 15

Page 102
Image 102
Brother FAX-8650P service manual WSW04 Transfer facility setting