V - 18
WSW06 (Pause key setting and 2nd dial tone detection)
Selector
No. Function Setting and Specifications
1
|
3
Pause key setting and 2nd dial
tone detection
No.123
000: No pause
001: 3.5 sec. WAIT
010: 7 sec. WAIT
011: 10.5 sec. WAIT
100: 14 sec. WAIT
110: 2nd dial tone detection
only in pulse dialing (DP)
system
101:2nd dial tone detection
111:both in DP and push-button
(PB) dialing system
4
|
6
Detection of international tone
No.456
000:50 ms
001:210 ms
010:500 ms
011:800 ms
100:900 ms
101:1.5 sec.
110:2.0 sec.
111:2.5 sec.
7No. of 2nd dial tone detection
times 0: Once 1: Twice
82nd dial tone interrupt detecting
time 0: 30 ms 1: 50 ms
NOTE: Selectors 4 through 8 are not applicable in those countries where no dial tone detection is