WSW34 (Function setting 12)

 

 

 

 

 

 

 

 

 

Selector

Function

 

 

Setting and Specifications

No.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

 

 

 

 

 

Not used.

 

 

 

 

 

5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

No. 6

7

 

 

 

6

Number of DTMF tone signals for

0

0

:

3

 

inhibiting the detection of CNG

0

1

:

2

 

7

 

during external TAD operation

1

0

:

1

 

 

 

1

1

:

OFF

 

 

 

 

 

 

 

CNG detection when the external

0:

Only when the

1: Always

8

telephone is connected with a line

 

equipment detects

 

 

TAD mode

 

itself being called

 

 

 

 

 

 

 

 

Selectors 6 and 7: Number of DTMF tone signals for inhibiting the detection of CNG during external TAD operation

If the equipment receives this specified number of DTMF tone signals during external TAD operation, it will not detect CNG afterwards.

If these selectors are set to "1, 1," the CNG detection will not be inhibited.

Selector 8: CNG detection when the external telephone is connected with a line in TAD

If this selector is set to "0," the equipment will detect a CNG signal only when it detects itself being called. If the external telephone is connected with a line before the equipment detects itself being called, the equipment will not longer detect a CNG signal.

If this selector is set to"1," the equipment will detect a CNG signal every time the external telephone is connected with a line, even without detecting itself being called.

 

 

WSW35 (Function setting 13)

 

 

 

 

Selector

Function

 

Setting and Specifications

No.

 

 

 

 

 

 

 

 