WSW17 (Function setting 2)
Selector | Function |
| Setting and Specifications | ||||
No. |
| ||||||
|
|
|
|
|
| ||
|
|
|
|
|
|
| |
|
| No. 1 | 2 |
|
|
| |
1 |
| 0 | 0 | : | No alarm | ||
0 | 1 | : | Always valid | ||||
2 | |||||||
| 1 | X | : | Valid except when | |||
|
| ||||||
|
|
|
|
| 'call reservation' | ||
|
|
|
|
| is selected. | ||
|
|
|
|
|
|
| |
3 | Power failure report output | 0: | ON |
| 1: | OFF | |
|
|
|
|
|
|
| |
4 | Calendar clock/prompt alternate | 0: | No |
| 1: | Yes | |
display |
| ||||||
|
|
|
|
|
| ||
|
|
|
|
| |||
5 | Calendar clock type | 0: | U.S.A. type 1: | European type | |||
|
|
|
|
|
|
| |
6 | Not used. |
|
|
|
|
| |
|
|
|
|
|
|
| |
7 | 0: | OFF |
| 1: | ON | ||
|
|
|
|
|
|
| |
8 | Not used. |
|
|
|
|
| |
|
|
|
|
|
|
|
NOTE: Selector 4 is not applicable to those models having a
•Selectors 1 and 2:
These selectors activate or deactivate the alarm function which sounds an alarm when the communication is completed with the handset being off the hook.
•Selector 3: Power failure report output
This selector determines whether or not the equipment outputs a power failure report when the power comes back on.
•Selector 4: Calendar clock/prompt alternate display
If this selector is set to "1," the calendar clock and the prompt "INSERT DOCUMENT" appear alternately on the LCD while the equipment is on standby; if it is set to "0," only the calendar clock appears.
•Selector 5: Calendar clock type
If this selector is set to "0" (USA), the MM/DD/YY hh:mm format applies; if it is set to "1" (Europe), the DD/MM/YY hh:mm format applies: DD is the day, MM is the month, YY is the last two digits of the year, hh is the hour, and mm is the minute.
•Selector 7:
Setting this selector to "1" makes the equipment receive calls without ringer sound if the ring delay is set to 0.