V - 30
WSW17 (Function setting 2)
Selector
No. Function Setting and Specifications
1
2Off-hook alarm
No. 1 2
0 0 :No alarm
0 1 :Always valid
1X: Valid except when
'call reservation'
is selected.
3Power failure report output 0: ON 1: OFF
4Calendar clock/prompt alternate
display 0: No 1: Yes
5Calendar clock type 0: U.S.A. type 1: European type
6Not used.
7Non-ring reception 0: OFF 1: ON
8Not used.
NOTE: Selector 4 is not applicable to those models having a 2-row LCD.
lSelectors 1 and 2: Off-hook alarm
These selectors activate or deactivate the alarm function which sounds an alarm when the
communication is completed with the handset being off the hook.
lSelector 3: Power failure report output
This selector determines whether or not the equipment outputs a power failure report when the
power comes back on.
lSelector 4: Calendar clock/prompt alternate display
If this selector is set to "1," the calendar clock and the prompt "INSERT DOCUMENT" appear
alternately on the LCD while the equipment is on standby; if it is set to "0," only the calendar clock
appears.
lSelector 5: Calendar clock type
If this selector is set to "0" (USA), the MM/DD/YY hh:mm format applies; if it is set to "1" (Europe),
the DD/MM/YY hh:mm format applies: DD is the day, MM is the month, YY is the last two digits of
the year, hh is the hour, and mm is the minute.
lSelector 7: Non-ring reception
Setting this selector to "1" makes the equipment receive calls without ringer sound if the ring delay
is set to 0.