3.DETAILED DESCRIPTION OF MAINTENANCE-MODE FUNCTIONS
3.1EEPROM Parameter Initialization
nFunction
The equipment initializes the parameters, user switches, and firmware switches registered in the EEPROM, to the initial values. Entering the function code 01 initializes all of the EEPROM areas, but entering 91 does not initialize some areas, as listed below.
Function code | 01 |
| 91 |
Data item |
| ||
|
|
| |
|
|
|
|
|
|
| |
User switches |
|
| These will be |
Firmware switches |
|
| initialized |
Remote activation code |
|
|
|
Activity report | All of these will be. |
|
|
| initialized |
|
|
Station ID data |
|
| |
|
|
| |
Outside line number |
|
|
|
Telephone function registration |
|
| These will not be |
|
| initialized | |
|
|
| |
Speed dialing |
|
|
|
Group dialing |
|
|
|
|
|
| |
EEPROM customizing code | This will not be initialized. | ||
(Note that the first digit of the | |||
| initialized to "0." If the code is 1001, for example, it | ||
| will be initialized to 0001.) |
| |
|
|
|
|
NOTE: If you replace the main PCB with one used for other facsimile equipment, carry out this procedure and then customize the EEPROM
nOperating Procedure
(1)Press the 0 and 1 keys (or the 9 and 1 keys according to your need) in this order in the initial stage of the maintenance mode.
The "PARAMETER INIT" will appear on the LCD.
(2)Upon completion of parameter initialization, the equipment returns to the initial stage of the maintenance mode.
V - 4