V - 21
WSW08 (Dial tone setting 2)
Selector
No. Function Setting and Specifications
1
|
3
1st dial tone detection time
length
No. 123
000: 50 ms
001: 210 ms
010: 500 ms
011: 800 ms
100: 900 ms
101: 1.5 sec.
110: 2.0 sec.
111: 2.5 sec.
4
5
Time-out length for 1st and 2nd
dial tone detection
No. 4 5
00: 10 sec.
01: 20 sec.
10: 15 sec.
11: 30 sec.
6
|
8
Detection level of 1st dial tone
and busy tone before dialing
No. 678
000: -21 dBm
001: -24 dBm
010: -27 dBm
011: -30 dBm
100: -33 dBm
101: -36 dBm
110: -39 dBm
111: -42 dBm
NOTE: The WSW08 is not applicable in those countries where no dial tone detection is supported,
e.g., U.S.A.
lSelectors 1 through 3: 1st dial tone detection time length
Upon detection of the 1st dial tone for the time length set by these selectors, the equipment starts
dialing.
This setting is effective only when selectors 1 through 3 of WSW05 are set to “1,1,1.”
lSelectors 4 and 5: Time-out length for 1st and 2nd dial tone detection
These selectors set the time-out length for the 1st and 2nd dial tone detection so that the
equipment waits dial tone input for the specified time length and disconnects itself from the line
when no dial tone is inputted.