WSW37 (Function setting 15)

 

 

 

 

Selector

Function

 

Setting and Specifications

No.

 

 

 

 

 

 

 

 

1

 

 

 

Not used.

 

 

8

 

 

 

 

 

 

 

WSW38 (Function setting 16)

Selector

Function

 

 

Setting and Specifications

No.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

No. 1

2

 

 

 

1

Setting of the Equalizer

0

X

Automatic

 

 

2

1

0

: Fixed to 4 points

 

 

 

 

 

1

1

: Fixed to 16 points

 

 

 

 

 

 

3

Sending Level of Guard Tone at

0:

Normal - 7 db

1:

Normal

 

Phase 2

 

 

 

 

 

 

 

 

 

 

4

Stepping Down the Transmission

0:

2400 bps 1:

4800 bps

 

Speed at Fallback Each

 

 

 

 

 

 

 

 

 

 

 

 

 

 

No. 5

6

 

 

 

 

 

0

0

For higher transmission speed

5

Automatic Control of Modem's

 

 

than the current setting

0

1

: No change from the current

6

EQM Gain for Proper

 

 

setting

 

 

 

Transmission Speed Choice

 

 

 

 

 

1

0

: For lower transmission speed

 

 

 

 

 

 

than the current setting

 

 

1

1

: For further lower transmission

 

 

 

 

than the setting made by 1, 0

7

Not used.

 

 

 

 

 

8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTE: WSW38 takes effect only in the V. 34 mode.

 

 

 

 

Selectors 1 and 2: Setting of the Equalizer

These selectors set the equalizer's training level to be applied if the facsimile equipment fails to send training due to weak line connection. If these selectors are set to "0, X," the modem will automatically set the appropriate training level.

Selector 3: Sending Level of Guard Tone at Phase 2

This selector sets the sending level of guard tone for 1800 Hz to be sent at Phase 2 in the V. 34 mode.