| WSW37 (Function setting 15) | |
|
|
|
|
Selector | Function |
| Setting and Specifications |
No. |
| ||
|
|
| |
|
|
|
|
1 |
|
|
|
Not used. |
|
| |
8 |
|
|
|
|
|
|
|
WSW38 (Function setting 16)
Selector | Function |
|
| Setting and Specifications | |||
No. |
|
| |||||
|
|
|
|
|
| ||
|
|
|
|
|
|
| |
|
| No. 1 | 2 |
|
|
| |
1 | Setting of the Equalizer | 0 | X | Automatic |
|
| |
2 | 1 | 0 | : Fixed to 4 points | ||||
| |||||||
|
| ||||||
|
| 1 | 1 | : Fixed to 16 points | |||
|
|
|
|
|
| ||
3 | Sending Level of Guard Tone at | 0: | Normal - 7 db | 1: | Normal | ||
| Phase 2 |
|
|
|
|
| |
|
|
|
|
| |||
4 | Stepping Down the Transmission | 0: | 2400 bps 1: | 4800 bps | |||
| Speed at Fallback Each |
|
|
|
|
| |
|
|
|
|
|
|
| |
|
| No. 5 | 6 |
|
|
| |
|
| 0 | 0 | For higher transmission speed | |||
5 | Automatic Control of Modem's |
|
| than the current setting | |||
0 | 1 | : No change from the current | |||||
6 | EQM Gain for Proper | ||||||
|
| setting |
|
| |||
| Transmission Speed Choice |
|
|
|
| ||
| 1 | 0 | : For lower transmission speed | ||||
|
| ||||||
|
|
|
| than the current setting | |||
|
| 1 | 1 | : For further lower transmission | |||
|
|
|
| than the setting made by 1, 0 | |||
7 | Not used. |
|
|
|
|
| |
8 |
|
|
|
|
| ||
|
|
|
|
|
| ||
|
|
|
|
|
|
| |
NOTE: WSW38 takes effect only in the V. 34 mode. |
|
|
|
|
•Selectors 1 and 2: Setting of the Equalizer
These selectors set the equalizer's training level to be applied if the facsimile equipment fails to send training due to weak line connection. If these selectors are set to "0, X," the modem will automatically set the appropriate training level.
•Selector 3: Sending Level of Guard Tone at Phase 2
This selector sets the sending level of guard tone for 1800 Hz to be sent at Phase 2 in the V. 34 mode.
V - 47