V - 10
Firmware Switches (WSW01 through WSW41) Continued
WSW No. Function Reference Page
WSW37 Function setting 15 V-47
WSW38 Function setting 16 V-47
WSW39 Function setting 17 V-49
WSW40 Function setting 18 V-50
WSW41 Function setting 19 V-51
nn Operating Procedure
(1)Press the 1 and 0 keys in this order in the initial stage of the maintenance mode.
The equipment displays the "WSW00" on the LCD and becomes ready to accept a firmware
switch number.
(2)Enter the desired number from the firmware switch numbers (01 through 41).
The following appears on the LCD:
WSWXX =0 0 0 0 0 0 0 0
(3)Use the and keys to move the cursor to the selector position to be modified.
(4)Enter the desired number using the 0 and 1 keys.
(5)Press the Set key. This operation saves the newly entered selector values onto the EEPROM
and readies the equipment for accepting a firmware switch number.
(6)Repeat steps (2) through (5) until the modification for the desired firmware switches is
completed.
(7)Press the Set or Stop key to return the equipment to the initial stage of the maintenance
mode.
NOTES:To cancel this operation and return the equipment to the initial stage of the
maintenance mode during the above procedure, press the Stop key.
If there is a pause of more than one minute after a single-digit number is entered for
double-digit firmware switch numbers, the equipment will automatically return to the
initial stage of the maintenance mode.
nn Note
The user-accessible selectors of the firmware switches are shaded in the tables given on the
following pages.