3.3ADF Performance Test
nFunction
The equipment counts the documents fed by the automatic document feeder (ADF) and displays the count on the LCD for checking the ADF performance.
nOperating Procedure
(1)Set documents. (Allowable up to the ADF capacity.) The "DOC. READY" will appear on the LCD.
(2)Press the 0 and 8 keys in this order.
While counting the documents, the equipment feeds them in and out, displaying the current count on the LCD as shown below.
Current count (1st page in this example)
(3)After showing the final count, the equipment beeps for one second. To return the equipment to the initial stage of the maintenance mode, press the Stop key.