•Selectors 1 through 3: Pause key setting and 2nd dial tone detection
Selectors |
| ||
1 | 2 | 3 |
|
|
|
|
|
0 | 0 | 0 | No WAIT is inserted even if the Pause key is pressed. |
|
|
|
|
0 | 0 | 1 | If you press the Pause key during dialing, the facsimile equipment will |
0 | 1 | 0 | insert WAIT as defined in the above table. |
0 | 1 | 1 | If the Pause key is pressed repeatedly, the equipment inserts the |
1 | 0 | 0 | specified WAIT multiplied by the number of depressions. It applies also |
|
|
| |
|
|
| in |
|
|
|
|
1 | 0 | 1 | When these selectors are set to "1, 0, 1": |
1 | 1 | 0 | If you press the Pause key during dialing, the equipment will wait for the |
1 | 1 | 1 | 2nd dial tone to be sent via the communications line. |
|
|
| |
|
|
| When these selectors are set to "1, 1, 0" or "1, 1, 1": |
|
|
| If you press the Pause key during dialing, the equipment will first wait for |
|
|
| the 2nd dial tone to be sent via the communications line. After that, the |
|
|
| equipment will insert a WAIT of 3.5 seconds. |
|
|
| If no 2nd dial tone is received within the specified time length (set by |
|
|
| WSW08), the equipment will disconnect the line if in automatic dialing, or |
|
|
| it will start transmitting the dial signal if given after depression of the |
|
|
| Pause key in |
|
|
| (In those countries where no dial tone detection function is supported, |
|
|
| setting these selectors to "1, 0, 1," "1, 1, 0," or "1, 1, 1" inserts a WAIT of |
|
|
| 3.5 seconds.) |
|
|
|
|
•Selectors 4 through 6: Detection of international tone
Upon detection of the 2nd dial tone for the time length specified by these selectors, the equipment starts dialing.
This setting is effective only when the 2nd dial tone detection function is activated by selectors 1 through 3 (Setting 101, 110, or 111).
This function does not apply in those countries where no dial tone detection function is supported.
•Selector 7: No. of 2nd dial tone detection times
This selector sets the number of dial tone detection times required for starting dialing.
•Selector 8: 2nd dial tone interrupt detecting time
This selector sets the allowable time length of an interrupt which should not be interpreted as an interrupt in the 2nd tone dialing.
V - 19