Table 44 — Fan Performance - 48PDD05 Vertical Units

AIRFLOW

 

 

 

 

 

AVAILABLE EXTERNAL STATIC PRESSURE (in. wg)

 

 

 

(Cfm)

 

0.2

 

0.4

0.6

 

 

0.8

 

1.0

Rpm

 

Bhp

Rpm

 

Bhp

Rpm

 

Bhp

Rpm

 

Bhp

Rpm

 

Bhp

 

 

 

 

 

 

1200

504

 

0.16

613

 

0.23

710

 

0.31

798

 

0.40

881

 

0.49

1300

527

 

0.19

632

 

0.27

725

 

0.35

810

 

0.44

890

 

0.54

1400

551

 

0.22

652

 

0.31

741

 

0.40

823

 

0.49

900

 

0.59

1500

576

 

0.26

673

 

0.35

759

 

0.44

838

 

0.54

912

 

0.65

1600

600

 

0.30

694

 

0.40

777

 

0.50

854

 

0.60

926

 

0.71

1700

626

 

0.35

716

 

0.45

797

 

0.55

871

 

0.66

941

 

0.78

1800

651

 

0.40

739

 

0.51

817

 

0.62

889

 

0.73

957

 

0.85

1900

677

 

0.46

762

 

0.57

838

 

0.69

908

 

0.80

974

 

0.93

2000

703

 

0.52

785

 

0.64

859

 

0.76

927

 

0.88

992

 

1.01

 

 

 

 

 

 

 

 

 

 

 

AIRFLOW

 

 

 

 

 

AVAILABLE EXTERNAL STATIC PRESSURE (in. wg)

 

 

 

 

1.2

 

1.4

1.6

 

 

1.8

 

2.0

(Cfm)

 

 

 

 

 

 

Rpm

 

Bhp

Rpm

 

Bhp

Rpm

 

Bhp

Rpm

 

Bhp

Rpm

 

Bhp

1200

957

 

0.59

1030

 

0.70

1098

 

0.80

1163

 

0.91

1225

 

1.03

1300

964

 

0.64

1035

 

0.75

1102

 

0.86

1166

 

0.98

1227

 

1.10

1400

973

 

0.70

1042

 

0.81

1107

 

0.92

1170

 

1.04

1231

 

1.17

1500

983

 

0.76

1050

 

0.87

1114

 

0.99

1176

 

1.12

1235

 

1.24

1600

994

 

0.82

1060

 

0.94

1122

 

1.06

1183

 

1.19

1241

 

1.32

1700

1007

 

0.89

1071

 

1.02

1132

 

1.14

1191

 

1.27

1248

 

1.41

1800

1021

 

0.97

1083

 

1.10

1143

 

1.23

1200

 

1.36

1256

 

1.50

1900

1037

 

1.05

1097

 

1.18

1155

 

1.32

1211

 

1.45

1266

 

1.60

2000

1053

 

1.14

1111

 

1.27

1168

 

1.41

1223

 

1.55

1276

 

1.70

LEGEND

 

 

 

 

 

 

NOTES:

 

 

 

 

 

 

 

Bhp --Brake Horsepower

 

 

 

 

 

 

1. Maximum continuous BHP is 2.0.

 

 

 

 

 

 

 

 

 

 

 

 

2. See General Fan Performance Notes.

 

 

 

 

 

Table 45 — Fan Performance - 48PDE05 Vertical Units

AIRFLOW

 

 

 

 

 

AVAILABLE EXTERNAL STATIC PRESSURE (in. wg)

 

 

 

(Cfm)

 

0.2

 

0.4

0.6

 

 

0.8

 

1.0

 

Rpm

 

Bhp

Rpm

 

Bhp

Rpm

 

Bhp

Rpm

 

Bhp

Rpm

 

Bhp

1200

509

 

0.16

618

 

0.24

714

 

0.32

802

 

0.41

884

 

0.50

1300

533

 

0.19

637

 

0.27

730

 

0.36

814

 

0.45

894

 

0.55

1400

557

 

0.23

658

 

0.31

746

 

0.40

828

 

0.50

905

 

0.60

1500

582

 

0.27

679

 

0.36

764

 

0.45

843

 

0.55

917

 

0.66

1600

608

 

0.31

701

 

0.40

783

 

0.50

860

 

0.61

931

 

0.72

1700

634

 

0.36

723

 

0.46

803

 

0.56

877

 

0.67

947

 

0.79

1800

660

 

0.41

747

 

0.52

824

 

0.63

896

 

0.74

963

 

0.86

1900

686

 

0.47

770

 

0.58

846

 

0.70

915

 

0.82

981

 

0.94

2000

713

 

0.54

795

 

0.66

868

 

0.78

935

 

0.90

999

 

1.02

 

 

 

 

 

 

 

 

 

 

 

AIRFLOW

 

 

 

 

 

AVAILABLE EXTERNAL STATIC PRESSURE (in. wg)

 

 

 

(Cfm)

 

1.2

 

1.4

1.6

 

 

1.8

 

2.0

 

Rpm

 

Bhp

Rpm

 

Bhp

Rpm

 

Bhp

Rpm

 

Bhp

Rpm

 

Bhp

1200

961

 

0.60

1033

 

0.70

1101

 

0.81

1166

 

0.92

1228

 

1.03

1300

968

 

0.65

1039

 

0.76

1106

 

0.87

1169

 

0.98

1230

 

1.10

1400

977

 

0.70

1046

 

0.82

1111

 

0.93

1174

 

1.05

1234

 

1.17

1500

987

 

0.77

1054

 

0.88

1118

 

1.00

1180

 

1.12

1239

 

1.25

1600

999

 

0.83

1065

 

0.95

1127

 

1.07

1187

 

1.20

1245

 

1.33

1700

1013

 

0.90

1076

 

1.03

1137

 

1.15

1196

 

1.28

1253

 

1.42

1800

1027

 

0.98

1089

 

1.11

1148

 

1.24

1206

 

1.37

1261

 

1.51

1900

1043

 

1.06

1103

 

1.20

1161

 

1.33

1217

 

1.47

1271

 

1.61

2000

1060

 

1.16

1118

 

1.29

1175

 

1.43

1229

 

1.57

1282

 

1.72

LEGEND

 

 

 

 

 

 