Chapter 7 Board-control Commands
Extended Board Statistics (16H) | Page 7 - 41 |
Extended
Board
Statistics (16H)
Command
Format
The RF3880 adapter keeps track of several types of board statistics. With the Extended Board Statistics command you can retrieve the extended set of statistics kept by the adapter. The statistics are valid only as long as power is kept to the system. This command reports the statistics by recording them in the area of system memory specified in the command Parameter Block; this statistics structure is returned in addition to the normal Status Block.
You can clear the internal statistics table at any time by issuing the command with the CLR bit of the Options field set. No data transfer occurs when the CLR bit is set.
The Parameter Block format for the Extended Board Statistics command looks like this:
Address |
|
| Byte Memory Address |
| ||
Offset | Offset + 0 |
| Offset + 1 |
| Offset + 2 | Offset + 3 |
|
|
| ||||
|
|
|
|
|
| |
00H |
|
| Command Identifier |
| ||
|
|
|
|
|
| |
04H | Reserved |
|
| Addr. Mod. | Adapter ID = FFH | |
|
|
|
|
|
| |
08H |
|
| VME Memory Address |
| ||
|
|
|
|
|
| |
0CH |
|
|
| Reserved |
| |
10H | Command = 16H |
| Options |
| Reserved | |
|
|
|
|
|
|
|
14H |
|
|
| Reserved |
| |
|
|
|
|
|
| |
18H |
|
|
| Reserved |
| |
|
|
|
|
|
|
|
Description of Fields
Table 100: Extended Board Statistics Parameter Block
Each of the fields of the Parameter Block are explained below:
Command Identifier
This field is used to identify the Status Block associated with a Parameter Block. It must be a unique value.
Adapter ID
This field must be set to FFH.
Address Modifier
This is the value to be used by the adapter as an Address Modifier when writing extended statistics to memory. This field is not used when the CLR bit is set.
VME Memory Address
This is the system memory address at which you wish to have the adapter place the Extended Statistics Data Structure. This field is not used when the CLR bit is set.
User’s Guide | 21020285 D |