Chapter 7 Board-control Commands

 

Board Statistics (06H)

Page 7 - 13

Options

This field has the following bit-meanings:

BITS

7

6

5

4

3

2

1

0

 

 

 

 

 

 

 

 

 

 

 

0

 

 

 

CLR

Table 69: Options Field

CLR Clear - This bit allows you to clear the internal statistic values currently stored. (Statistics returned by both the 06H and 16H commands will be cleared.) It is useful if you wish to keep track of statistics during a specific period. The only other time statistic values get cleared is during adapter reset.

0 Command is used to return internal statistics to specified system memory address.

1 Command is used to clear the internal statistics table. VMEbus Address fields are not used.

The Data Structure returned from the Board Statistics command is illustrated on the next page.