Cisco Systems ATA 186 RingCadence, Bit Number, Definition, Description, Value Type, Range, 5-20

Models: ATA 188 ATA 186

1 166
Download 166 pages 49.11 Kb
Page 80
Image 80
RingCadence

Chapter 5 Parameters and Defaults

Optional Feature Parameters

Table 5-4 SigTimer Parameter Bit Definitions

Bit Number

Definition

 

 

0-7

Call waiting period—The period between each burst of call-waiting tone.

 

Range: 0 to 255 in 0.1 seconds

 

Default: 100 (0x64=100 seconds)

 

 

8-15

Not used for SCCP.

 

 

16-25

Reserved—Should be set to 0.

 

 

26-27

Minimum hook flash time—The minimum on-hook time required for a hook flash event.

 

Range: 0 to 3

 

Default: 0 (60 ms)

 

Other possible values: 1=100 ms, 2=200 ms, 3=300 ms.

 

 

28-31

Maximum hook flash time—The maximum on-hook time allowed for a hook flash event.

 

Range: 0 to 15

 

Default: 0 (1000 ms)

 

Other possible values: 1=100 ms, 2=200 ms, 3=300 ms, 4=400 ms, 5=500 ms, 6=600 ms, 7=700 ms, 8=800

 

ms, 9=900 ms, 10=1000 ms, 11=1100 ms, 12=1200 ms, 13=1300 ms, 14=1400 ms, 15=1500 ms.

 

 

RingCadence

Description

Use this parameter to specify the internal and external ringer cadence pattern, expressed as a triplet of integers “a,b, and c”.

a—Number of seconds to turn the ring ON.

b—Number of seconds to turn the ring OFF.

c—The ring frequency, fixed at 25.

Value Type

List of three integer values, separated by commas

Range

1-65535

Default

2, 4, 25

Recommended Values:

United States —2,4,25

Sweden — 1,5,25

Voice Configuration Menu Access Code

929