Cisco Systems ATA 188 Specific Call-Progress Tone Parameter Information, DialTone, Description

Models: ATA 188 ATA 186

1 166
Download 166 pages 49.11 Kb
Page 83
Image 83
Specific Call-Progress Tone Parameter Information

Chapter 5 Parameters and Defaults

Optional Feature Parameters

CallWaitTone = "1,30959,0,2392,0, 0, 1600, 4000,11200" (approximately -10 dBm)

ConfirmTone = "1,30959,0,2392,0, 0, 480, 480,1920" (approximately -10 dBm)

Specific Call-Progress Tone Parameter Information

Brief descriptions, and lists of default values and the voice configuration menu code for each Cisco ATA tone parameter, appear in the following sections:

DialTone, page 5-23

BusyTone, page 5-24

ReorderTone, page 5-24

RingbackTone, page 5-25

CallWaitTone, page 5-25

ConfirmTone, page 5-26

DialTone

Description

The Cisco ATA plays the dial tone when it is ready to accept the first digit of a remote address to make an outgoing call.

This parameter is for specifying the inside dial tone in SCCP. The outside dial tone in SCCP is fixed at 450Hz+540Hz@-6dBm. The inside dial tone is the tone that the telephone plays when a phone inside the PBX goes off-hook. The outside dial tone is the tone that the telephone plays when a phone inside the PBX is connected to the PSTN.

Default values for the nine-integer array

ntone—2

freq0—31538

freq1—30831

level0—1380

level1—1740

steady—1

on-time—0

off-time—0

total time to play tone—1000

Voice Configuration Menu Access Code

920

Cisco ATA 186 and Cisco ATA 188 Analog Telephone Adaptor Administrator’s Guide (SCCP)

 

Ol-3141-01

5-23

 

 

 