CREATE FACILITY

CREATE FACILITY

Create an RTR facility and ready it for transaction traffic.

Format

CREATE FACILITY [facility_name]

Command Qualifiers

Defaults

/ALL_ROLES=node-list

/NOALL_ROLES

/BACKEND=backend-list

/NOBACKEND

/BALANCE

/NOBALANCE

/CALL_OUT=role-list

/NOCALL_OUT

/CLUSTER

/NOCLUSTER

/FRONTEND=frontend-list

/NOFRONTEND

/NODE[=node-list]

/NODE=default-node-list

/OUTPUT[=file-spec]

/OUTPUT=stdout

/REPLY_CHECKSUM

NOREPLY_CHECKSUM

/RESOURCE_MANAGER=resource-list

/ROUTER=router-list

/NOROUTER

Description

The CREATE FACILITY command configures (defines on a node) an RTR facility and readies it for transaction traffic (that is, establishes links to other the participating nodes).

The command must be issued on all participating nodes before any application programs using the facility are started.

Note

Router nodes must have all backend nodes defined and Backend nodes must have all router nodes defined.

Routers need only be defined with the frontends that they can connect to.

Frontends need only be defined with the routers they can connect to.

Parameters

facility_name

Specifies the name of the facility to be created.

Any application program which uses this facility must specify the same name when it calls rtr_open_channel( ).

Facility names can contain up to thirty-one characters. Letters, numbers and underline characters are all valid, but the first character of a facility name must be a letter.

Facility names are not case sensitive.

The default value for facility_name is RTR$DEFAULT_FACILITY.

The /ROUTER qualifier, and at least one of /FRONTEND or /BACKEND must be specified.