4: Configuring the Web Interface
Field Name | Definition |
Alarm Trigger | The trigger expression used to generate an SNMP |
| trap. |
|
|
[untitled dropdown field] |
|
|
|
OID Type Value | The value that uniquely identifies an object to |
| the SNMP agent. |
|
|
Trap Number | The trap type defined in the MIB. |
|
|
Community | The password used to authenticate the traps |
|
|
Server IP | The address of the server running the SNMP. |
|
|
Body | The text or content of the notification. |
|
|
4.After selecting and completing the Notification Entry dialog box, select the OK button.
5.Select the Apply Changes button at the bottom of the ACS configuration window to save your configuration.
Port DCD Alarm Notification
You can configure the Notification form to monitor the DCD signal such that the system will generate an alarm in any of the following events:
•A serial console cable is removed from the console server
•A server/network equipment attached to the console is powered down.
•The configuration also enables you to detect if a modem that is in use is still powered on and active.
1.From the Notification form, select the Action (Email, SNMP Trap or Pager).
2.Click the Add button.
3.Enter the Alarm Trigger: Port DCD
4.Configure the parameters of the action
5.Select Apply Changes
118 | AlterPath Console Server User Manual |