4: Configuring the Web Interface

Field Name

Definition

Alarm Trigger

The trigger expression used to generate an SNMP

 

trap.

 

 

[untitled dropdown field]

 

 

 

OID Type Value

The value that uniquely identifies an object to

 

the SNMP agent.

 

 

Trap Number

The trap type defined in the MIB.

 

 

Community

The password used to authenticate the traps

 

 

Server IP

The address of the server running the SNMP.

 

 

Body

The text or content of the notification.

 

 

4.After selecting and completing the Notification Entry dialog box, select the OK button.

5.Select the Apply Changes button at the bottom of the ACS configuration window to save your configuration.

Port DCD Alarm Notification

You can configure the Notification form to monitor the DCD signal such that the system will generate an alarm in any of the following events:

A serial console cable is removed from the console server

A server/network equipment attached to the console is powered down.

The configuration also enables you to detect if a modem that is in use is still powered on and active.

1.From the Notification form, select the Action (Email, SNMP Trap or Pager).

2.Click the Add button.

3.Enter the Alarm Trigger: Port DCD

4.Configure the parameters of the action

5.Select Apply Changes

118

AlterPath Console Server User Manual

Page 124
Image 124
Cyclades ACS48, 2.3.0 user manual Port DCD Alarm Notification, OID Type Value, Trap Number, Server IP, Body