4: Configuring the Web Interface

Field Name

Definition

Connection Protocol

The method you will use to access the serial ports.

 

Cyclades recommend SSH to ensure that all data and

 

authentication information are encrypted. Other

 

options are Telnet and Raw Data (for un-negotiated

 

plain socket connections).

 

 

Flow Control

The method of flow control used by the attached

 

devices (Hardware, Software, or None).

 

 

Baud Rate

The serial speed on each console port, which should

 

match the equipment you will connect to. The

 

recommended Baud Rate is 9600.

 

 

Data Size

Number of data bits used by the attached devices (5,

 

6, 7 or 8).

 

 

Parity

Parity used by the attached devices (None, Odd, or

 

Even).

 

 

Stop Bits

Number of stop bits used by the attached devices.

 

 

Authentication Req’d

Selecting this checkbox sets the system to require

 

authentication to access the ports. This is done in the

 

local database in the ACS.

 

 

If you require port authentication, then you must add users through Wizard Step 3: Access.

To configure other authentication methods (e.g., LDAP, RADIUS, TACACS), select the Expert button to switch to Expert Mode and select: Security > Authentication.

3.Select Apply Changes to save configuration to Flash.

4.Select the Next button or proceed to the next section, Step 3: Access.