CYV15G0404DXB

Table 7. Output Register Bit Assignments

Signal Name

BYPASS ACTIVE

DECODER

(DECBYPx = 0)

(DECBYP = 1)

 

RXSTx[2] (LSB)

COMDETx

RXSTx[2]

 

 

 

RXSTx[1]

DOUTx[0]

RXSTx[1]

 

 

 

RXSTx[0]

DOUTx[1]

RXSTx[0]

 

 

 

RXDx[0]

DOUTx[2]

RXDx[0]

 

 

 

RXDx[1]

DOUTx[3]

RXDx[1]

 

 

 

RXDx[2]

DOUTx[4]

RXDx[2]

 

 

 

RXDx[3]

DOUTx[5]

RXDx[3]

 

 

 

RXDx[4]

DOUTx[6]

RXDx[4]

 

 

 

RXDx[5]

DOUTx[7]

RXDx[5]

 

 

 

RXDx[6]

DOUTx[8]

RXDx[6]

 

 

 

RXDx[7] (MSB)

DOUTx[9]

RXDx[7]

 

 

 

When the 10B/8B decoder is bypassed, the framed 10-bit value is presented to the associated output register, along with a status output signal indicating if the character in the output register is one of the selected framing characters. The bit usage and mapping of the external signals to the raw 10B transmission character is shown in Table 8.

Table 8. Decoder Bypass Mode

Signal Name

Bus Weight

10 Bit Name

RXSTx[2] (LSB)

COMDETx

 

 

 

 

RXSTx[1]

20

a

RXSTx[0]

21

b

RXDx[0]

22

c

RXDx[1]

23

d

RXDx[2]

24

e

RXDx[3]

25

i

RXDx[4]

26

f

RXDx[5]

27

g

RXDx[6]

28

h

RXDx[7] (MSB)

29

j

The COMDETx status output operates the same regardless of the bit combination selected for character framing by the FRAMCHARx latch. COMDETx is HIGH when the character in the output register contains the selected framing character at the proper character boundary, and LOW for all other bit combina- tions.

When the low-latency framer and half rate receive port clocking are also enabled, the framer stretches the recovered clock to the nearest 20-bit boundary such that the rising edge of RXCLKx+ occurs when COMDETx is present on the associated output bus.

When the Cypress or alternate mode framer is enabled and half rate receive port clocking is also enabled, the output clock is not modified when framing is detected, but a single pipeline stage may be added or subtracted from the data stream by the framer logic such that the rising edge of RXCLKx+ occurs when COMDETx is present on the associated output bus.

This adjustment only occurs when the framer is enabled. When the framer is disabled, the clock boundaries are not adjusted, and COMDETx may be asserted during the rising edge of RXCLKx– (if an odd number of characters were received following the initial framing).

Receive Status Bits

When the 10B/8B decoder is enabled, each character presented at the output register includes three associated status bits. These bits are used to identify

If the contents of the data bus are valid

The type of character present

The state of receive BIST operations

Character violations

These conditions often overlap; for example, a valid data character received with incorrect running disparity is not reported as a valid data character. It is instead reported as a decoder violation of some specific type. This implies a hierarchy or priority level to the various status bit combinations. The hierarchy and value of each status are listed in Table 11.

A second status mapping, listed in Table 11, is used when the receive channel is configured for BIST operation. This status is used to report receive BIST status and progress.

BIST Status State Machine

When a receive path is enabled to look for and compare the received data stream with the BIST pattern, the RXSTx[2:0] bits identify the present state of the BIST compare operation.

The BIST state machine has multiple states, as shown in Figure 2 and Table 11. When the receive PLL detects an out-of-lock condition, the BIST state is forced to the Start-of-BIST state, regardless of the present state of the BIST state machine. If the number of detected errors ever exceeds the number of valid matches by greater than 16, the state machine is forced to the WAIT_FOR_BIST state where it monitors the receive path for the first character of the next BIST sequence (D0.0). Also, if the Elasticity Buffer ever hits an overflow/underflow condition, the status is forced to the BIST_START until the buffer is re-centered (approximately nine character periods).

To ensure compatibility between the source and destination systems when operating in BIST modes, the sending and receiving ends of the link must use the same receive clock configuration.

Device Configuration and Control Interface

The CYP(V)15G0404DX is highly configurable through the configuration interface. The configuration interface allows the device to be configured globally or allows each channel to be configured independently. Table 9 lists the configuration latches within the device including the initialization value of the latches upon the assertion of RESET. Table 10 shows how the latches are mapped in the device. Each row in the Table 10 maps to a 8-bit latch bank. There are 16 such write-only latch banks. When WREN = 0, the logic value in the DATA[7:0] is latched to the latch bank specified by the values in ADDR[3:0]. The second column of Table 10 specifies the channels associated with the corre- sponding latch bank. For example, the first three latch banks (0,1 and 2) consist of configuration bits for channel A. The latch banks

Document #: 38-02097 Rev. *B

Page 19 of 44

[+] Feedback

Page 19
Image 19
Cypress CYV15G0404DXB manual Device Configuration and Control Interface, Output Register Bit Assignments Signal Name