CYV15G0404DXB

3-Level Select Inputs

Each 3-Level select inputs reports as two bits in the scan register. These bits report the LOW, MID, and HIGH state of the associated input as 00, 10, and 11 respectively.

JTAG ID

The JTAG device ID for the CYV15G0404DXB is ‘0C811069’x

.

Receive Character Status Bits

RXSTx[2:0]

Priority

Description

Normal Status

Receive BIST Status

 

 

(Receive BIST = Enabled)

 

 

 

000

7

Normal character received. The valid Data

BIST Data Compare. Character compared correctly.

 

 

character on the output bus meets all the

 

 

 

formatting requirements of Data characters

 

 

 

listed in Table 14.

 

001

7

Special code detected. The valid special

BIST Command Compare. Character compared

 

 

character on the output bus meets all the

correctly.

 

 

formatting requirements of Special Code

 

 

 

characters listed in Table 15, but is not the

 

 

 

presently selected framing character or a

 

 

 

decoder violation indication.

 

010

2

Receive Elasticity buffer underrun/overrun

BIST Last Good. Last Character of BIST sequence

 

 

error. The receive buffer was not able to

detected and valid.

 

 

add/drop a K28.5 or framing character

 

011

5

Framing character detected. This indicates

 

 

 

that a character matching the patterns identified

 

 

 

as a framing character (as selected by

 

 

 

FRAMCHARx) was detected. The decoded

 

 

 

value of this character is present in the

 

 

 

associated output bus.

 

100

4

Codeword violation. The character on the

BIST Last Bad. Last Character of BIST sequence

 

 

output bus is a C0.7. This indicates that the

detected invalid.

 

 

received character cannot be decoded into any

 

 

 

valid character.

 

101

1

Loss of sync. This indicates a PLL Out of Lock

BIST Start. Receive BIST is enabled on this channel,

 

 

condition

but character compares have not yet commenced. This

 

 

 

also indicates a PLL Out of Lock condition, and

 

 

 

Elasticity Buffer overflow/underflow conditions.

110

6

Running disparity error. The character on the

BIST Error. While comparing characters, a mismatch

 

 

output bus is a C4.7, C1.7, or C2.7.

was found in one or more of the decoded character bits.

111

3

Reserved

BIST Wait. The receiver is comparing characters. but

 

 

 

has not yet found the start of BIST character to enable

 

 

 

the LFSR.

Document #: 38-02097 Rev. *B